PCE-RVI 2 V1R: Default spindles R2-R7 + optional R1
Spindle
R1
(optional)
R2
R3
R4
R5
R6
R7
rpm
Viscosity in mPa s
0.3
33.3 x 10
3
133.3 x
10
3
333.3 x
10
3
666.6 x
10
3
1.3 x 10
6
3.33 x 10
6
13.3 x 10
6
0.5
2 x 10
4
8 x 10
4
2 x 10
5
4 x 10
5
8 x 10
5
2 x 10
6
8 x 10
6
0.6
16.6 x 10
3
66.6 x 10
3
166.6 x
10
3
333.3 x
10
3
666.6 x
10
3
1.6 x 10
6
6.6 x 10
6
1
1 x 10
4
4 x 10
4
1 x 10
5
2 x 10
5
4 x 10
5
1 x 10
6
4 x 10
6
1.5
6.6 x 10
3
26.6 x 10
3
66.6 x 10
3
133.3 x
10
3
266.6 x
10
3
666.6 x
10
3
2.6 x 10
6
2
5 x 10
3
2 x 10
4
5 x 10
4
1 x 10
5
2 x 10
5
5 x 10
5
2 x 10
6
2.5
4 x 10
3
16 x 10
3
4 x 10
4
8 x 10
4
16 x 10
4
4 x 10
5
1.6 x 10
6
3
3.3 x 10
3
13.3 x 10
3
33.3 x 10
3
66.6 x 10
3
133.3 x
10
3
333.3 x
10
3
1.3 x 10
6
4
2.5 x 10
3
1 x 10
4
2.5 x 10
4
5 x 10
4
1 x 10
5
25 x 10
4
1 x 10
6
5
2 x 10
3
8 x 10
3
2 x 10
4
4 x 10
4
8 x 10
4
2 x 10
5
8 x 10
5
6
1.6 x 10
3
6.6 x 10
3
16.6 x 10
3
33.3 x 10
3
66.6 x 10
3
166.6 x
10
3
66.6 x 10
3
10
1 x 10
3
4 x 10
3
1 x 10
4
2 x 10
4
4 x 10
4
1 x 10
5
4 x 10
5
12
8.33 x 10
2
3.3 x 10
3
8.3 x 10
3
16.6 x 10
3
33.3 x 10
3
83.3 x 10
3
333.3 x
10
3
20
5 x 10
2
2 x 10
3
5 x 10
3
1 x 10
4
2 x 10
4
5 x 10
4
2 x 10
5
30
3.33 x 10
2
1.3 x 10
3
3.3 x 10
3
6.6 x 10
3
13.3 x 10
3
33.3 x 10
3
133.3 x
10
3
50
2 x 10
2
8 x 10
2
2 x 10
3
4 x 10
3
8 x 10
3
2 x 10
4
8 x 10
4
60
1.66 x 10
2
6.6 x 10
2
1.6 x 10
3
3.3 x 10
3
6.6 x 10
3
16.6 x 10
3
66.6 x 10
3
100
1 x 10
2
4 x 10
2
1 x 10
3
2 x 10
3
4 x 10
3
1 x 10
4
4 x 10
4
200
50
2 x 10
2
5 x 10
2
1 x 10
3
2 x 10
3
5 x 10
3
2 x 10
4
Increme
nt
1 mPa s
1 mPa s
10 mPa s
10 mPa s
10 mPa s
100 mPa s
100 mPa s
10 Accessories
10.1 Adapter for small sample volumes
Measurement range
Model V1L: 1.5* - 200000 mPa s/cP
Model V1R: 25* - 3300000 mPa s/cP
*High rotational speeds required for very low-viscosity measurements can have a negative influence on
viscosity readings.
*Viscosity measurements have to be carried out under laminar flow conditions as turbulent flow conditions
can cause erroneously high viscosity values.
Description
The adapter for small fluid volumes is available as an accessory for precision spindles which rotate inside
a sample container. The container fits into a water jacket which enables water circulation and thus precise
temperature control (between -10 °C and 100 °C). The adapter for the special spindle set must be
ordered separately. It is normally used for testing very small fluid volumes (8-13ml)
This accessory part is available to order in two versions:
Standard adapter
Adapter with temperature sensor in the lower cap to allow direct sample temperature monitoring