Manual 

Receipt of the device 

Please check the packaging for any obvious signs of damage before opening. 
If the external packaging is found to be damaged, please notify the delivery company before opening. 
 
After unpacking the viscometer, check the device for any obvious signs of damage. Should there be any 
visible signs of damage, please notify PCE Instruments. 

5.1 

Delivery content 

1.  1 x rack 
2.  1 x rotational viscometer PCE-RVI 2 
3.  1 x set of spindles L1 to L4 or R2 to R7 
4.  1 x laboratory stand 
5.  1 x instruction manual 
6.  1 x temperature sensor 

7.  1 x guard for measuring spindle 
8.  1 x assembly tool 
9.  1 x carrying case 
10.  1 x power cable 
11.  1 x storage stand for measuring spindles 

Keep the packaging, in case the instrument needs to be returned. Parts that are damaged by 
inappropriate packaging or inappropriate delivery 

are not covered by the manufacturer’s warranty. 

 

5.2 

Installation 

For an appropriate installation proceed as follows 

 

Remove the nut off the rack 

 

Place the rack on the stand in the correct position. The thread 
must be pointed in the direction of the stand

’s nut. 

 

Using the provided assembly tool and nut, screw the rack and the 
stand together. 

 

Attach the back pole to the clamp of the rack. 

 

Move the lever down to fix the device.

 

 

Place the device on a solid and even surface. 

 

Slide the plastic cover of the back pole downwards to remove. 

 

The protection is only allowed to be moved to the side when the 
plastic protection has been successfully moved down. 

 

Balance the device with the rotary bases on the front of the stand. 
The levelling indicator on the top will show you when the device is 
levelled adequately. 

 

Connect the device to the power supply system. 

5.3 

Connecting to the mains 

Ensure that your power supply is correctly earthed and your device is set 
to the correct voltage. 
 

 

Summary of Contents for PCE-RVI 2

Page 1: ...s UK Ltd Units 12 13 Southpoint Business Park Ensign way Hampshire Southampton United Kingdom SO31 4RF From outside UK 44 Tel 0 2380 98703 0 Fax 0 2380 98703 9 info pce instruments com www pce instrum...

Page 2: ...Viscometer PCE RVI 2 V1R 13 10 Accessories 14 10 1 Adapter for small sample volumes 14 10 2 Adapter for low viscosity materials 17 10 3 Adapter for spiral movements 19 11 Calibration 23 12 Troublesho...

Page 3: ...ved PCE Instruments personnel The device should not be placed on a surface with the user interface i e keyboard face down No unauthorised technical changes should be carried out on the device The devi...

Page 4: ...Manual 4 4 System description...

Page 5: ...Manual 5...

Page 6: ...or inappropriate delivery are not covered by the manufacturer s warranty 5 2 Installation For an appropriate installation proceed as follows Remove the nut off the rack Place the rack on the stand in...

Page 7: ...acteristic property of a liquid It is a measure of the internal friction within a liquid when individual layers within the liquid are brought into motion against each other Viscosity values are highly...

Page 8: ...m Plastic Under static conditions these fluids appear to be solid In order to carry out an analysis of these fluids it is necessary for them to be subjected to a yield stress so that they show charact...

Page 9: ...Press Enter to confirm your language of choice The following notification then appears With the Up or Down keys either select the unit for the viscosity SI mPa s or CGS cP Press Enter to confirm your...

Page 10: ...l be printed The viscometer sends a permanent print job in COMPUTER mode The viscometer and the computer have to be connected The data format in PRINTER mode is not suitable for small printers The fol...

Page 11: ...Now the rotation rate rpm starts to flash Press the Up or Down keys to change the values and confirm the entry by pressing the Enter button The parameter range informs you about the maximum measurable...

Page 12: ...al alignment or even damaged The spindle L4 and R7 have to immersed up to the boundary point The spindles are made out of AISI 316 stainless steel Every spindle is identifiable by its engraving 8 3 St...

Page 13: ...10 4 3 x 10 5 2 5 2 4 x 10 3 1 2 x 10 4 4 8 x 10 4 2 4 x 10 5 3 2 x 10 3 1 x 10 4 4 x 10 4 2 x 10 5 4 1 5 x 10 3 7 5 x 10 3 3 x 10 4 1 5 x 10 5 5 1 2 x 10 3 6 x 10 3 2 4 x 10 4 1 2 x 10 5 6 1 x 10 3...

Page 14: ...2 1 3 x 10 3 3 3 x 10 3 6 6 x 10 3 13 3 x 10 3 33 3 x 10 3 133 3 x 10 3 50 2 x 10 2 8 x 10 2 2 x 10 3 4 x 10 3 8 x 10 3 2 x 10 4 8 x 10 4 60 1 66 x 10 2 6 6 x 10 2 1 6 x 10 3 3 3 x 10 3 6 6 x 10 3 16...

Page 15: ...ume The spindle should be covered completely Hang the desired spindle 6 onto the spindle hook 7 Attach the hook to the screw 8 Insert the spindle with hook and screw into the sample container Insert t...

Page 16: ...s S R have been calculated based on the assumption that the fluids have Newtonian characteristics PCE RVI 2 V1R TR8 TR11 Spindle TR8 TR9 TR10 TR11 rpm Viscosity in mPa s 0 3 166 6 x 10 3 833 3 x 10 3...

Page 17: ...ously high viscosity values Description An adapter for low viscosity materials is available as an accessory for precision spindles which rotate within a sample container To maintain an accurate temper...

Page 18: ...inge to fill the container The sample amount needed is very small 18 ml Check the filling level The spindle should be completely covered to be the correct sample amount Hang the LCP spindle 9 onto the...

Page 19: ...s cP High rotational speed for the measurement of low viscosity values can have a negative influence on the readings Viscosity measurements have to be carried out under laminar conditions Turbulent fl...

Page 20: ...of the stand Insert the rack into the security socket 1 Use the lower stopper ring 2 to fix the rack to the security socket Tighten it with the screw but be careful that you do not screw too tight Att...

Page 21: ...opper ring with screw 3 Sliding knob for the adapter 4 Fixing lever for the measuring element 5 Upper stopper ring with screw 6 ON OFF switch 7 Rack 8 Power indicator 9 Counterweight 10 T spindle 11 C...

Page 22: ...ter and choose a spindle and a rotational speed Turn on 6 the adapter Check if the power indicator lights up 8 Selection table for PCE RVI 2 V1L Spindle PA PB PC PD PE PF rpm Viscosity in mPa s 0 3 62...

Page 23: ...0 3 833 2 x 10 3 Increment 5 mPa s 10 mPa s 25 mPa s 50 mPa s 125 mPa s 250 mPa s 11 Calibration Contact PCE Instruments 12 Troubleshooting The device does not work Check power connection Check switch...

Page 24: ...use them or give them to a recycling company which disposes of the devices in line with law If you have any questions please contact PCE Instruments 15 Contact If you have any questions about our rang...

Page 25: ...9872 Meschede Deutschland Tel 02903 976 99 0 Fax 02903 976 99 29 info pce instruments com www pce instruments com deutsch Bedienungsanleitung Rotationsviskosimeter PCE RVI 2 Version 1 1 Erstelldatum 1...

Page 26: ...2 V1L 13 9 2 Viskosimeter PCE RVI 2 V1R 13 10 Zubeh r 14 10 1 Adapter f r kleine Probenvolumina 14 10 2 Adapter f r niederviskose Materialien 17 10 3 Adapter f r spiralf rmige Bewegungen 19 11 Kalibr...

Page 27: ...aturbereich verwendet werden Das Geh use darf nur durch Fachpersonal der PCE Deutschland GmbH ge ffnet werden Nehmen Sie selbst auch keine technischen nderungen am Ger t vor Dieses Benutzer Handbuch w...

Page 28: ...BETRIEBSANLEITUNG 4 4 Systembeschreibung 4 1 Vorderansicht...

Page 29: ...BETRIEBSANLEITUNG 5 4 2 R ckansicht...

Page 30: ...ion F r die sachgem e Installation des Viskosimeters gehen Sie wie folgt vor Entfernen Sie die Mutter von der Zahnstange Platzieren Sie die Zahnstange in der richtigen Position auf dem St nder Das Gew...

Page 31: ...er einen gro en Messbereich 6 2 Wichtige Hinweise Viskosit t Die Viskosit t ist eine charakterisierende Eigenschaft von Fl ssigkeiten Sie ist ein Ma f r die innere Reibung der Fl ssigkeit wenn einzeln...

Page 32: ...i zunehmender Schergeschwindigkeit nennt man pseudoplastisch oder auch scherverd nnend Bekannte pseudoplastische Fl ssigkeiten sind Lacke Milch Tinte oder Marmelade Plastisch Unter statischen Bedingun...

Page 33: ...uswahl zu best tigen Folgende Anzeige erscheint als N chstes Mit der Up oder Down Taste k nnen Sie die Einheit f r die Viskosit t SI mPa s oder CGS cP ausw hlen Best tigen Sie die Eingabe durch Dr cke...

Page 34: ...Modus sendet das Viskosimeter einen dauerhaften Druckauftrag Dazu sollte das Viskosimeter mit einem PC verbunden sein Das Datenformat im PRINTER Modus ist nicht geeignet f r kleine Drucker Folgende A...

Page 35: ...er Enter Taste Daraufhin beginnt die Geschwindigkeit U min zu blinken Dr cken Sie die Up oder Down Taste um den Wert zu ndern und best tigen Sie die Eingabe mit der Enter Taste Der Parameter range inf...

Page 36: ...deln L4 und R7 m ssen bis zum Begrenzungspunkt eingetaucht werden Die Spindeln sind aus AISI 316 Rost freiem Stahl Jede Spindel ist durch eine Gravur eindeutig identifizierbar 8 3 Messung Starten Dr c...

Page 37: ...x 10 3 1 5 x 10 4 6 x 10 4 3 x 10 5 2 5 2 4 x 10 3 1 2 x 10 4 4 8 x 10 4 2 4 x 10 5 3 2 x 10 3 1 x 10 4 4 x 10 4 2 x 10 5 4 1 5 x 10 3 7 5 x 10 3 3 x 10 4 1 5 x 10 5 5 1 2 x 10 3 6 x 10 3 2 4 x 10 4 1...

Page 38: ...0 3 13 3 x 10 3 33 3 x 10 3 133 3 x 10 3 50 2 x 10 2 8 x 10 2 2 x 10 3 4 x 10 3 8 x 10 3 2 x 10 4 8 x 10 4 60 1 66 x 10 2 6 6 x 10 2 1 6 x 10 3 3 3 x 10 3 6 6 x 10 3 16 6 x 10 3 66 6 x 10 3 100 1 x 10...

Page 39: ...obenmenge Die Spindel sollte vollst ndig bedeckt sein H ngen Sie die gew nschte Spindel 6 an den Spindelhaken 7 Befestigen Sie den Haken an der Schraube 8 F hren Sie die Spindel mit Schraube und Haken...

Page 40: ...hergeschwindigkeiten S R wurden aufgrund der Annahme errechnet dass die Fl ssigkeiten newtonsche Eigenschaften haben PCE RVI 2 V1R TR8 TR11 Spindel TR8 TR9 TR10 TR11 U min Viskosit t in mPa s 0 3 166...

Page 41: ...erweise zu hohe Viskosit tswerte Beschreibung Der Adapter zur Messung niederviskoser Stoffe ist ein Zubeh rteil f r eine Pr zisionsspindel die in einem Probenbeh lter rotiert Dieser Beh lter passt in...

Page 42: ...lasen im Beh lter verbleiben Verwenden Sie zum Bef llen des Beh lters eine gro e Spritze Die ben tigte Probenmenge ist sehr klein 18 ml berpr fen Sie den F llstand Bei korrekter Probenmenge sollte die...

Page 43: ...9400000 mPa s cP Modell V1R 1660 100000000 mPa s cP Hohe Rotationsgeschwindigkeiten zur Messung geringer Viskosit tswerte k nnen einen negativen Einfluss auf die Ablesewerte haben Viskosit tsmessungen...

Page 44: ...gsbuchse 1 an der Zahnstange an Schieben Sie den unteren Feststellring 2 auf die Zahnstange und befestigen Sie ihn mit der Schraube Achten Sie darauf die Schraube nicht zu fest anzuziehen Bringen Sie...

Page 45: ...stellring mit Schraube 3 Schieberiegel f r Adapter 4 Befestigungshebel f r Messvorrichtung 5 Oberer Feststellring mit Schraube 6 EIN AUS Schalter 7 Zahnstange 8 Betriebsanzeige 9 Gegengewicht 10 T Spi...

Page 46: ...skosimeter und den Adapter mit dem Stromnetz Schalten Sie das Viskosimeter ein und w hlen Sie eine Spindel sowie eine Geschwindigkeit aus Schalten Sie den Adapter EIN 6 Kontrollieren Sie ob die Betrie...

Page 47: ...mbH 12 Fehlersuche Das Ger t funktioniert nicht berpr fen Sie die Netzverbindung berpr fen Sie die Schalterposition Die Spindel dreht sich nicht mittig berpr fen Sie die korrekte Ausrichtung der Spind...

Page 48: ...V PCE Deutschland GmbH Im Langel 4 59872 Meschede Zur Umsetzung der ElektroG R cknahme und Entsorgung von Elektro und Elektronikaltger ten nehmen wir unsere Ger te zur ck Sie werden entweder bei uns w...

Reviews: