background image

 

 

CALIBRATI

Calibration m

for annual ca

 

1.  First

zero

2.  Turn

3.  Pres

calib

posi

4.  The 

calib

figur

5.  Sav

) in 2

 

6.  Follo

the 

to yo

 

7.  Aga

End

 

 

If you can't s

between  75

If you want t

) calibration 

Above  calib

pressure) or

 

 

 

 

ON MODE 

mode is only 

alibration, 

t, please ma

o procedure. 

n the meter o

ss 

  & 

bration  mode

itive (+) pres

meter has d

bration press

re by pressin

e the calibra

2 seconds , t

ow the same

LCD now dis

our pressure

in save the c

'' and ''CA'' a

save by pres

.0  and  85.0

to skip positiv

point. 

bration  is  an

r from 0 to -1

applicable fo

nually set the

off. 

 simultan

e,  make  sur

sure calibrat

 

defaulted as 

sure source 

ng 

 key to

ation point by

the meter au

 

e procedure a

splays '' -80 

e standard if 

 

calibration po

appears in an

 

ss 

 key, i

,  or  check  (

ve (+) calibra

n  example  fo

00 psi (Nega

or a standard

e display to z

neously ''CA'

re  the  pressu

tion 

80 psi calibra

is not 80 psi

o set calibrat

y pressing 

uto-skip to the

as step 4 for

,0 '' and sm

needed. 

oint by press

nother 2 seco

i.e. no ''SA'' 

(b)  if  you  en

ation when e

or  model  82

ative pressur

d Manomete

zero (no pres

' appears on

ure  unit  to  b

ation point, t

 , to increas

tion point as 

 key , ''SA'

e negative p

r the negativ

all ''CA'' (Se

sing  

 ke

onds, the me

appeared, p

nter  the  righ

entered to the

2100,  i.e.  th

re). 

er calibrator o

ssure applied

n the display

be  pointed  u

he adjustabl

e the figure 

required. 

' and small ''

ressure (-) p

e pressure c

e Fig. K ), d

ey, ''SA'' and 

eter turns ba

lease check

ht  positive  p

e Calibration

e  pressure 

or any qualifi

d to the conn

y, (See Fig. 

under  the  ar

e pressure r

by pressing 

'CA” appears

point for next 

calibration po

o the necess

''CA'' appea

ck to the nor

: (a) The cal

ressure  (+) 

n mode, pres

range  is  fro

ed meter ca

nector), refer

I) the mete

rrow  mark     

range in from

 key , o

s on the disp

calibration m

oint by press

sary calibrat

ars in 2 seco

rmal mode (S

ibration pres

or  negative 

s to 

 skip

om  0  to  +10

 

libration facil

r to the Manu

r enters to t

      is  psi  st

m 78.0 to 82.0

r decrease t

play (See Fig

mode. 

sing  

  ke

ion figure ref

nds and then

See Fig . L). 

ssure source

pressure  (-

p to negative

00psi  (Positi

lity 

ual 

the 

art 

0 if 

the 

g. J 

ey , 

fer 

n '' 

 

e is 

-)  .  

e (-

ive 

Summary of Contents for PCE-P05

Page 1: ...Instruction Manual HVAC Meter PCE PXX ...

Page 2: ...TO POWER OFF SLEEP FUNCTION 4 MODE OPTIONS 4 MAINTENANCE 5 CALIBRATION MODE 6 CALIBRATION POINT REFERENCE 7 MANUAL ZERO SETTING 7 TROUBLESHOOTING 7 REPLACING THE BATTERY 7 OPERATING CONDITIONS 7 SPECIFICATION 8 RS232 OUTPUT 8 WARRANTY 8 RETURN AUTHORIZATION 8 ...

Page 3: ...essure in psi that is referenced to ambient pressure and Differential pressure a measure of the difference two pressures 11 pressure units are selectable for Imperial and Metric in the different area bar mmHg ozin kgcm psi inH2 kPa ftH2O inHg cmH2O mbar Please check the tubing is not leakage or damaged before using CONVERSION Manometer PSI Inch of H2O mbar kg cm PCE P05 5 138 345 0 35 PCE P15 15 4...

Page 4: ... the modes on Default s y and relative in the middl y again and ord mode is d r 3 seconds t etal lug 5mm chasing the u TION cally in appr ger periods o he screen at ter paper off ble user sele ast used ed during the s of operatio setting and o e clock starts le deft of Fi the unit cycl displayed on to turn off the m plastic lug unit rox 20 minut of time you t which tinge ctable start u e last oper...

Page 5: ...t to the f zero before m clean the cas age the unit s e reading F op of the LC splay to show he unit return ce between t process con cle through the bottom o minates for a gure when ca shipping To ong time usin will maintain factory or a measurement se of the Ma s case with a Fig E CD and tile w as 0 0 o ns to the norm two pressure nection ope bar mmHg of the display approx 30 se alibration is b o...

Page 6: ...s nother 2 seco i e no SA b if you en ation when e or model 82 ative pressur d Manomete zero no pres appears on ure unit to b ation point t to increas tion point as key SA e negative p r the negativ all CA Se sing ke onds the me appeared p nter the righ entered to the 2100 i e th re er calibrator o ssure applied n the display be pointed u he adjustabl e the figure required and small ressure p e pr...

Page 7: ...DIF function the differential pressure value is larger than maximum display digit Err 3 appears on the display Err 4 When you set zero make sure you have disconnected the tubing no pressure applied to the connector Then if you see an Err 4 appears on the display it means the sensor or meter damaged Return the unit to the store you purchased for repaired Err 4 will be also appeared while the tube o...

Page 8: ...he D sub 9P type connector onto computer s Com 1 or 2 port or 3 Start to set up RS232 software by inserting the CD ROM or Floppy diskette 4 When installing the RS232 software please follow the operation manual procedure in the software package WARRANTY The meter is warranted to be free from defects in material and workmanship for a period of one year from the date of purchase This warranty covers ...

Reviews: