Congratulations  on  your  purchase  of  the  Manometer!  This  instrument  is  portables  battery  operated  pressure 

measuring device. 

The  Manometer  is  ideal  for  HVAC/R  technicians  measuring  pressure  level,  Medical  equipment  computer 

peripherals, pneumatic Controls. 

INTRODUCTION 

  The meter will display all LCD segments when it is first turned on for approx. 3 seconds. Though you 

might have seen DATALOGGER, Y/M/D, REL, AVG ... these are not available for the meter. The meter 

with data logger features named 8205D/821 5D/8280D/821 OOD. Please contact the store or the place 

you purchased. 

  The LCD is divided into two distinct sections: One large (Primary) top screen and one smaller right- 

bottom  bottom  screens  (relative  Clock),  The  2  display  areas  keep  you  constantly  updated  with  the) 

pressure measurements. 

  The  Meter  measures  Gauge  pressure-a  measure  of  pressure  in  psi  that  is  referenced  to  ambient 

pressure and Differential pressure - a measure of the difference two pressures. 

  11 pressure units are selectable for Imperial and Metric in the different area: bar, mmHg, ozin², kgcm², 

psi, inH2, kPa, ftH2O|, inHg, cmH2O, mbar. 

  Please check the tubing is not leakage or damaged before using 

CONVERSION  

Manometer 

PSI 

Inch of 

H2O 

mbar 

kg/cm³ 

PCE-P05 

138 

345 

0,35 

PCE-P15 

15 

415 

1034 

1,05 

PCE-P30 

30 

830 

2068 

2,10 

PCE-P50 

100 

2768 

6895 

7,03 

CONROLS AND INDICATORS 

 

1.  Primary Data Screen displays pressure value. 

2. 

“-“

: Minus pressure display. 

3. 

MAX MIN

: pressure recorded. 

4. 

REC

: starts recording mode and displays max./min. pressure recorded,  

5. 

AVG

: Average records (N/A). 

6. 

DC

: power in Jack. 

7. 

RS232

: output port. 

8. 

H/M/S 

88:88:88: displays data for Hour / Minute / Second. 

9.       : Pressure unit indication. 

10. 

BAT

: Battery low indicator. 

11. 

DIF

: Differential pressure mode. 

12. 

“+”

: Positive pressure home plug. 

13. 

“-“

: Negative pressure hose plug. 

14. 

HOLD

: Freezes pressure reading. 

15. 

REL

: Establish a relative zero for the primary screen information. (N/A) 

 

 

Summary of Contents for PCE-P05

Page 1: ...Instruction Manual HVAC Meter PCE PXX ...

Page 2: ...TO POWER OFF SLEEP FUNCTION 4 MODE OPTIONS 4 MAINTENANCE 5 CALIBRATION MODE 6 CALIBRATION POINT REFERENCE 7 MANUAL ZERO SETTING 7 TROUBLESHOOTING 7 REPLACING THE BATTERY 7 OPERATING CONDITIONS 7 SPECIFICATION 8 RS232 OUTPUT 8 WARRANTY 8 RETURN AUTHORIZATION 8 ...

Page 3: ...essure in psi that is referenced to ambient pressure and Differential pressure a measure of the difference two pressures 11 pressure units are selectable for Imperial and Metric in the different area bar mmHg ozin kgcm psi inH2 kPa ftH2O inHg cmH2O mbar Please check the tubing is not leakage or damaged before using CONVERSION Manometer PSI Inch of H2O mbar kg cm PCE P05 5 138 345 0 35 PCE P15 15 4...

Page 4: ... the modes on Default s y and relative in the middl y again and ord mode is d r 3 seconds t etal lug 5mm chasing the u TION cally in appr ger periods o he screen at ter paper off ble user sele ast used ed during the s of operatio setting and o e clock starts le deft of Fi the unit cycl displayed on to turn off the m plastic lug unit rox 20 minut of time you t which tinge ctable start u e last oper...

Page 5: ...t to the f zero before m clean the cas age the unit s e reading F op of the LC splay to show he unit return ce between t process con cle through the bottom o minates for a gure when ca shipping To ong time usin will maintain factory or a measurement se of the Ma s case with a Fig E CD and tile w as 0 0 o ns to the norm two pressure nection ope bar mmHg of the display approx 30 se alibration is b o...

Page 6: ...s nother 2 seco i e no SA b if you en ation when e or model 82 ative pressur d Manomete zero no pres appears on ure unit to b ation point t to increas tion point as key SA e negative p r the negativ all CA Se sing ke onds the me appeared p nter the righ entered to the 2100 i e th re er calibrator o ssure applied n the display be pointed u he adjustabl e the figure required and small ressure p e pr...

Page 7: ...DIF function the differential pressure value is larger than maximum display digit Err 3 appears on the display Err 4 When you set zero make sure you have disconnected the tubing no pressure applied to the connector Then if you see an Err 4 appears on the display it means the sensor or meter damaged Return the unit to the store you purchased for repaired Err 4 will be also appeared while the tube o...

Page 8: ...he D sub 9P type connector onto computer s Com 1 or 2 port or 3 Start to set up RS232 software by inserting the CD ROM or Floppy diskette 4 When installing the RS232 software please follow the operation manual procedure in the software package WARRANTY The meter is warranted to be free from defects in material and workmanship for a period of one year from the date of purchase This warranty covers ...

Reviews: