4. Software 

 
PCE-IR 1000 series  portable  infrared  thermometer  has 

special  software  and  connecting  cable.  Users can set the unit, download the loggered

data and recording temperature curve  and through the software. 

 

4.1   System Requirements 

   Vista, XP or Windows 2000 operation system 
   USB interfacet 
   Hard disk with at least 30MByte free space 
   At least 128MByte RAM 
   CD-ROM Driver 

 

4.2     Installation and connection 

Please  insert  the  CD  to  CD-ROM  driv er.  Please  start  the  SETUP.EXE  on  the 

CD-ROM, and install the software follow the instructions of the wizard. 

 

   

  USB interface driver installation 

1) Insert  USB  Cable  into  computer’s  USB  port.  Computer  will  find  the  new 

hardware, and the following dialogue box appears: 

 
2) Choose the option of “NO, not for the time being (T)”, click “next” and the 

following dialogue box appear: 

 
3) Choose  “install  from  the  list  or  the designate  place  (advanced)  (S)”  click 

“next”, the following dialogue box appear. 

    

4) Click “browse” to find the USB file in CD. 

    

5) Click “confirm”, the following dialogue box appear: 
 
6) Click  “next”,  sometimes  the  system  will  come  up  the  following  the  prompt, 

then click “still continue”. 

Summary of Contents for PCE-IR 1300

Page 1: ...2 Fax 561 320 9176 info pce americas com www pce instruments com english www pce instruments com PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign way Hampshire Southampton United Kin...

Page 2: ...the parameters 2 7 Setup emissivity 2 8 Setup the Min Max function 2 9 Setup high and low alarm 2 10 Setup the temperature unit 2 11 Setup offset 3 Data Logger 3 1 Storing data 3 2 Datalogger recall...

Page 3: ...you will enter to another function setup e g press one time to enter to emissivity setup press it again will save emissivity and enter to MIN MAX setup and so on Up Laser With this button you can setu...

Page 4: ...2 1 3 External function introduction 1 Trigger 2 Battery compartment cover 3 USB interface 4 Telescope 4 1 2 3...

Page 5: ...7 seconds if no button is pressed 2 4 Setup the laser Pull the trigger keep it pressed and then press up button to activate or deactivate the laser The laser symbol in the display only if the trigger...

Page 6: ...r modify the requested value by pressing the up and down buttons Press mode button to save the value and enter to next function If you have not activated any button for 7 seconds the unit will not sav...

Page 7: ...button until enter the high alarm mode Press the up down button to set the alarm on or off When the signal of shows on the display it means the high alarm is activated After set high alarm you can pr...

Page 8: ...unit selecting mode and press the up down button to select the requested temperature unit Centigrade scale Fahrenheit scale 2 11 Setup offset In Hold mode press the mode button repeatedly until enter...

Page 9: ...showing a disk and an icon of MAX appear above the current temperature result The small numbers indicate the memory position You can choose the memory position from 1 2000 with the up down buttons Pr...

Page 10: ...Clear the memory In the Storing Data mode choose the memory position to 0 by pressing the down button Press the mode button will clear the memory The three buzzer signals confirms the successful clea...

Page 11: ...start the SETUP EXE on the CD ROM and install the software follow the instructions of the wizard USB interface driver installation 1 Insert USB Cable into computer s USB port Computer will find the ne...

Page 12: ...oftware the communication will be displayed in the status bar of the windows Choosethe correct COM Port via MENU Setup interface There will be a signal of PCE IR 1000 connected show on the left bottom...

Page 13: ...ak values Manual scaling can be done at any time using the control elements of the temperature axis 4 Stop the measurement To stop the current measurement please press the stop key Menu measurement st...

Page 14: ...2 1 5 Specifications 5 1 Optical Specifications PCE IR 1300 D S 120 1 PCE IR 1800 PCE IR 1600 D S 300 1...

Page 15: ...0 100 1 000adjustable Aim mode Laser telescope aim Signal processing MAX MIN Scan Hold Function Alarm functions Audible a nd visible HIGH LOW alarm Data storage 2000 point Backlight Three color Outpu...

Page 16: ...100ms 95 Emissivity 0 100 1 000 adjustable Aim mode Laser telescope aim Signal processing MAX MIN Scan Hold Function Alarm functions Audible a nd visible HIGH LOW alarm Data storage 2000 point Backli...

Page 17: ...e 100ms 95 Emissivity 0 100 1 000 adjustable Aim mode Laser telescope aim Signal processing MAX MIN Scan Hold Function Alarm functions Audible a nd visible HIGH LOW alarm Data storage 2000 point Backl...

Page 18: ...issivity 8 14 m Aluminum oxidized 0 2 0 4 Asbestos 0 95 Asphalt 0 95 Basalt 0 7 Ceramic 0 95 Concrete 0 95 Copper oxidized 0 4 0 8 Fabric 0 95 Glass plate 0 85 Gold 0 01 0 1 Gravel 0 95 Ice 0 98 Iron...

Reviews: