IX. CLEAR DATA MEMORY
To clear the memory of data logger, hold the REC button and turn the power on.
The following display will be shown in LCD. Users press the HOLD button to
confirm the clearance of memory. The unit is turned off after the memory is
cleared.
If users do not press the HOLD button in 8 seconds, the memory is not clear. This
timer could avoid users accidentally clear the memory.
X. RS-232 INTERFACE PROTOCOL
Baud Rate:
9600
Data Bits:
8
Stop Bit:
1
Parity:
None
Format:
ASCII