©  PCE Instruments 

 

Safety notes 

Please read this manual carefully and completely before you use the device for the first time. The 
device  may  only  be  used  by  qualified  personnel  and  repaired  by  PCE  Instruments  personnel. 
Damage or injuries caused by non-observance of the manual are excluded from our liability and 
not covered by our warranty. 
 

 

The device must only be used as described in this instruction manual. If used otherwise, 
this can cause dangerous situations for the user and damage to the meter. 

 

The instrument may only be used if the environmental conditions (temperature, relative 
humidity, …) are within the ranges stated in the technical specifications. Do not expose 
the device to extreme temperatures, direct sunlight, extreme humidity or moisture. 

 

Do not expose the device to shocks or strong vibrations. Never touch live components 
when measuring. There is a danger to life. 

 

Never touch the bare measuring tips, otherwise electric shocks may occur. 

 

Before each measurement, make sure that the correct measurement range is set and 
that the test leads are connected correctly. 

 

Resistance,  capacitance  and  temperature  measurements  as  well  as  diode  tests  (if 
applicable) may only be carried out in a voltage-free state. 

 

Before  replacing  the  batteries  or  the  fuses,  all  test  leads  must  be  removed  from  the 
meter. 

 

The case should only be opened by qualified PCE Instruments personnel. 

 

Never use the instrument when your hands are wet. 

 

You must not make any technical changes to the device. 

 

The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner, 
no abrasives or solvents. 

 

The device must only be used with accessories from PCE Instruments or equivalent. 

 

Before each use, inspect the case for visible damage. If any damage is visible, do not 
use the device. 

 

Do not use the instrument in explosive atmospheres. 

 

The measurement range as stated in the specifications must not be exceeded under 
any circumstances. 

 

Non-observance of the safety notes can cause damage to the device and injuries to 
the user. 

 

 

General warning sign 

Non-observance can cause damage to the device and injuries to the 
user. 

 

Warning: electrical voltage 

Non-observance can cause electric shock.

 

 
We do not assume liability for printing errors or any other mistakes in this manual. 
 
We expressly point to our general guarantee terms which can be found in our general terms of 
business. 
 
If you have any questions please contact PCE Instruments. The contact details can be found at 
the end of this manual. 
 
 
 

 

Summary of Contents for PCE-DC 50

Page 1: ...DC Clamp Meter User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change...

Page 2: ...ty and diode test 8 5 7 Capacitance measurement 9 5 8 Frequency and duty cycle 9 5 9 A current measurement AC DC 9 5 10 Temperature measurement 9 6 Function setting 10 6 1 Freeze measured value 10 6 2...

Page 3: ...l as diode tests if applicable may only be carried out in a voltage free state Before replacing the batteries or the fuses all test leads must be removed from the meter The case should only be opened...

Page 4: ...t measurement AC DC test leads Measurement range Resolution Accuracy 0 00 500 00 A 0 01 A DC 1 0 6 digits AC 1 5 30 digits 0 0 5000 0 A 0 1 A DC 1 0 6 digits AC 1 5 30 digits Voltage measurement AC DC...

Page 5: ...0 0 5000 0 nF 0 1 nF 3 5 10 digits 0 00 50 00 F 0 01 nF 3 5 10 digits 0 0 500 0 F 0 1 F 3 5 10 digits 0 000 5 000 mF 0 001 mF 2 0 10 digits Frequency measurement Measurement range Resolution Accuracy...

Page 6: ...fast acting AC bandwidth AC A AC V 50 Hz 400 Hz AC measurement True RMS Operating conditions 5 C 40 C 41 104 F max 80 RH at 31 C Storage conditions 20 C 60 C 4 140 F max 80 RH Power supply 9 V block b...

Page 7: ...er current clamp Indicator non contact voltage detection HOLD key display backlight ZERO key illumination MODE Bluetooth key Function rotary switch Display MAX MIN key Sockets for K type thermocouple...

Page 8: ...rect current Duty cycle AC Alternating current F and C Temperature unit MAX Maximum value T1 T2 T1 T2 Temperature input 1 and 2 difference MIN Minimum value n m M k Measured value sign Battery low Con...

Page 9: ...tip along the conductor to exclude false measurements due to twisted conductors If voltage is present the indicator for non contact voltage detection permanently glows in red 5 4 Current measurement A...

Page 10: ...the cover of the input sockets upwards Set the rotary switch to position Press the MODE key repeatedly until the continuity test icon appears on the display Plug the test leads into the measuring inpu...

Page 11: ...ottom 5 9 A current measurement AC DC Slide the cover of the input sockets upwards Set the rotary switch to position A Use the MODE key to select AC or DC Plug the test leads into the measuring input...

Page 12: ...ch the function on or off 6 4 Set measurement range You can influence the measurement ranges for the measuring functions voltage resistance capacitance frequency and A The default setting is automatic...

Page 13: ...ing Remove the test leads or temperature probes from the meter If you do not use the instrument for more than 60 days remove the batteries 7 1 Cleaning Wipe the meter regularly with a damp cloth 7 2 B...

Page 14: ...d pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devi...

Page 15: ...Unit 11 Southpoint Business Park Via Pesciatina 878 B Interno 6 Halkal Merkez Mah Ensign Way Southampton 55010 Loc Gragnano Pehlivan Sok No 6 C Hampshire Capannori Lucca 34303 K k ekmece stanbul Unit...

Reviews: