background image

 

 

©  PCE Instruments 

13 

 

PCE Instruments contact information 

 

Germany 

France 

Spain 

PCE Deutschland GmbH 

PCE Instruments France EURL 

PCE Ibérica S.L. 

Im Langel 26 

23, rue de Strasbourg 

Calle Mayor, 53 

D-59872 Meschede 

67250 Soultz-Sous-Forets 

02500 Tobarra (Albacete) 

Deutschland 

France  

España 

Tel.: +49 (0) 2903 976 99 0 

Téléphone: +33 (0) 972 3537 17  

Tel. : +34 967 543 548 

Fax: +49 (0) 2903 976 99 29 

Numéro de fax: +33 (0) 972 3537 18 

Fax: +34 967 543 542 

[email protected] 

[email protected] 

[email protected] 

www.pce-instruments.com/deutsch 

www.pce-instruments.com/french 

www.pce-instruments.com/espanol 

 

 

 

United Kingdom 

Italy 

Turkey 

PCE Instruments UK Ltd 

PCE Italia s.r.l. 

PCE Teknik Cihazları Ltd.Şti. 

Unit 11 Southpoint Business Park 

Via Pesciatina 878 / B-Interno 6 

Halkalı Merkez Mah. 

Ensign Way, Southampton 

55010 Loc. Gragnano 

Pehlivan Sok. No.6/C 

Hampshire  

Capannori (Lucca) 

34303 Küçükçekmece - 

İstanbul 

United Kingdom, SO31 4RF 

Italia 

Türkiye 

Tel: +44 (0) 2380 98703 0 

Telefono: +39 0583 975 114  

Tel: 0212 471 11 47 

Fax: +44 (0) 2380 98703 9 

Fax: +39 0583 974 824  

Faks: 0212 705 53 93 

[email protected] 

[email protected] 

[email protected] 

www.pce-instruments.com/english 

www.pce-instruments.com/italiano 

www.pce-instruments.com/turkish 

 

 

 

The Netherlands 

United States of America 

PCE Brookhuis B.V. 

PCE Americas Inc. 

Institutenweg 15 

1201 Jupiter Park Drive, Suite 8 

7521 PH Enschede 

Jupiter / Palm Beach 

Nederland 

33458 FL 

Telefoon: +31 (0)53 737 01 92 

USA 

[email protected] 

Tel: +1 (561) 320-9162 

www.pce-instruments.com/dutch 

Fax: +1 (561) 320-9176 

 

   

[email protected] 

 

 

www.pce-instruments.com/us 

 
 

 
 

 

 

Summary of Contents for PCE-DC 50

Page 1: ...DC Clamp Meter User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change...

Page 2: ...ty and diode test 8 5 7 Capacitance measurement 9 5 8 Frequency and duty cycle 9 5 9 A current measurement AC DC 9 5 10 Temperature measurement 9 6 Function setting 10 6 1 Freeze measured value 10 6 2...

Page 3: ...l as diode tests if applicable may only be carried out in a voltage free state Before replacing the batteries or the fuses all test leads must be removed from the meter The case should only be opened...

Page 4: ...t measurement AC DC test leads Measurement range Resolution Accuracy 0 00 500 00 A 0 01 A DC 1 0 6 digits AC 1 5 30 digits 0 0 5000 0 A 0 1 A DC 1 0 6 digits AC 1 5 30 digits Voltage measurement AC DC...

Page 5: ...0 0 5000 0 nF 0 1 nF 3 5 10 digits 0 00 50 00 F 0 01 nF 3 5 10 digits 0 0 500 0 F 0 1 F 3 5 10 digits 0 000 5 000 mF 0 001 mF 2 0 10 digits Frequency measurement Measurement range Resolution Accuracy...

Page 6: ...fast acting AC bandwidth AC A AC V 50 Hz 400 Hz AC measurement True RMS Operating conditions 5 C 40 C 41 104 F max 80 RH at 31 C Storage conditions 20 C 60 C 4 140 F max 80 RH Power supply 9 V block b...

Page 7: ...er current clamp Indicator non contact voltage detection HOLD key display backlight ZERO key illumination MODE Bluetooth key Function rotary switch Display MAX MIN key Sockets for K type thermocouple...

Page 8: ...rect current Duty cycle AC Alternating current F and C Temperature unit MAX Maximum value T1 T2 T1 T2 Temperature input 1 and 2 difference MIN Minimum value n m M k Measured value sign Battery low Con...

Page 9: ...tip along the conductor to exclude false measurements due to twisted conductors If voltage is present the indicator for non contact voltage detection permanently glows in red 5 4 Current measurement A...

Page 10: ...the cover of the input sockets upwards Set the rotary switch to position Press the MODE key repeatedly until the continuity test icon appears on the display Plug the test leads into the measuring inpu...

Page 11: ...ottom 5 9 A current measurement AC DC Slide the cover of the input sockets upwards Set the rotary switch to position A Use the MODE key to select AC or DC Plug the test leads into the measuring input...

Page 12: ...ch the function on or off 6 4 Set measurement range You can influence the measurement ranges for the measuring functions voltage resistance capacitance frequency and A The default setting is automatic...

Page 13: ...ing Remove the test leads or temperature probes from the meter If you do not use the instrument for more than 60 days remove the batteries 7 1 Cleaning Wipe the meter regularly with a damp cloth 7 2 B...

Page 14: ...d pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devi...

Page 15: ...Unit 11 Southpoint Business Park Via Pesciatina 878 B Interno 6 Halkal Merkez Mah Ensign Way Southampton 55010 Loc Gragnano Pehlivan Sok No 6 C Hampshire Capannori Lucca 34303 K k ekmece stanbul Unit...

Reviews: