PCE Instruments PCE-BSW 3 User Manual Download Page 4

 

 

 

©  PCE Instruments 

 

Technical specifications  

Model 

PCE-BSW 3 

PCE-BSW 7 

Weighing range 

0 … 3,000 g / 0 ... 6.6 lbs 

0 … 7,500 g / 0 … 16.5 lbs 

Resolution/readability (d) 

0.1 g 

1 g 

Accuracy class 

III 

Repeatability 

±0.3 g 

Linearity 

±0.3 g 

Settling time 

<0.5 s 

Operating temperature 

5 ... 25 °C 

Dimensions weighing plate 

190 x 235 mm / 7.5 x 9.3 in 

Calibration 

External calibration 

Overall dimensions 

287 x 271 x 127 mm / 11.3 x 10.7 x 5 in 

Total weight 

4.5 kg 

Interfaces 

Mains adaptor 

Output DC 9V, 200 0mA, outside minus, inside plus 

 

Factory settings  

 

PCE-BSW 3 

PCE-BSW 7 

Weighing range 

3,000 g 

7,500 g 

Weighing range "C-

.“ 

C-03 

C-7.5 

Readability, resolution "d-

“ 

d-01  

d-01  

Decimal places "dP-." 

dP-1 

dP-0 

Weight unit "UN-0." 

UN-00 

UN-00 

Display brightness "br-.

“ 

br-3 

br-3 

Power saving mode "PS-0.

“ 

PS-01 

PS-01 

Sensitivity "E-0.

“ 

E-03/E-01 

E-03/E-01 

Limit value function on/off "P-.

” 

P-OFF 

P-OFF 

Zero tracking "t0-" 

t0-OFF 

t0-OFF 

 
 

Delivery scope 

1 x compact balance 
1 x mains adaptor 
1 x user manual 
 

 

 
 

 

Summary of Contents for PCE-BSW 3

Page 1: ...CE BSW 3 and PCE BSW 7 User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last...

Page 2: ...al specifications 2 3 Factory settings 2 4 Delivery scope 2 5 Device description 3 6 First use of the balance 4 7 Function settings 4 7 1 Notes on changing the function settings 6 8 Charging the batte...

Page 3: ...s The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only...

Page 4: ...s 287 x 271 x 127 mm 11 3 x 10 7 x 5 in Total weight 4 5 kg Interfaces Mains adaptor Output DC 9V 200 0mA outside minus inside plus 3 Factory settings PCE BSW 3 PCE BSW 7 Weighing range 3 000 g 7 500...

Page 5: ...imit 7 lb kg g display of the set weight unit 8 Display 9 Net Weight net weight lights up when tared Cancel taring with 0 or T key 10 Zero lights up when zero is displayed 11 ON OFF key 12 Key for fun...

Page 6: ...dC 6 6 0 0 o Current programme version number Weighing range in kg Current voltage CE Err means the mains adaptor is connected Current weight on the weighing platform Power saving mode after 1 minute...

Page 7: ...dash line appears then the measured value and the calibration is finished F 3 Dual range balance not available FUNC 1 FUNC 2 Dual range not available T to change MODE to continue to F 4 F 4 AD convert...

Page 8: ...nown weight whether the balance displays correctly Otherwise you must adjust the balance see item 1 5 Changing the weight units You can select grammes g kilogrammes kg pounds lb and carats CT If one o...

Page 9: ...weighing material is not stable Keep the environmental conditions as stable as possible Remove objects Fix the weighing product Weighing is not correct No calibration No taring before weighing net wei...

Page 10: ...d pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devi...

Page 11: ...Merkez Mah Ensign Way Southampton 55010 Loc Gragnano Pehlivan Sok No 6 C Hampshire Capannori Lucca 34303 K k ekmece stanbul United Kingdom SO31 4RF Italia T rkiye Tel 44 0 2380 98703 0 Telefono 39 058...

Reviews: