PCE Instruments PCE-ABZ 100C User Manual Download Page 1

                                  USER MANUAL 

     PCE-ABZ/C SERIES 

PCE Americas Inc.

711 Commerce Way 

Suite 8 

Jupiter

FL-33458

USA

From outside US: +1

Tel: (561) 320-9162

Fax: (561) 320-9176

[email protected]

www.pce-instruments.com/english

www.pce-instruments.com

PCE Instruments UK Ltd.

Units 12/13 

Southpoint Business Park 

Ensign way

Hampshire / Southampton

United Kingdom, SO31 4RF

From outside UK: +44

Tel: (0) 2380 98703 0

Fax: (0) 2380 98703 9

[email protected]

Laboratory Balances

Summary of Contents for PCE-ABZ 100C

Page 1: ...0 9162 Fax 561 320 9176 info pce americas com www pce instruments com english www pce instruments com PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign way Hampshire Southampton Unite...

Page 2: ...9 9 Operation principles 10 10 Testing and calibration 11 11 External calibration calibration options 11 12 Internal calibration autocalibration 13 13 Connecting a balance to a computer or a printer...

Page 3: ...ith an internal calibration system for proper accuracy control during operation The user should also own weight standard of OIML F2 or F1 class for periodical control of the balance weight value state...

Page 4: ..._________________________________________________________ 4 3 General view Front view 1 pan 2 support pan 4 display LCD 5 keyboard 6 legs 7 water level Rear view 7 6 1 2 8 9 4 5 3 ON OFF Adjust switch...

Page 5: ...weighed mass key 0 numeric key zeroing balances for direct sale use only key numeric key data output print transmission key numeric key internal calibration on and off key Menu numeric key Menu key I...

Page 6: ...city Max 100g 200g Min load Min 10mg 10mg Reading unit d 0 1mg 0 1mg Verification unit e 1mg 1mg Tare range 100g 200g Accuracy class I Working temperature 18 30 C Weighing time 8s Pan dimension 90mm B...

Page 7: ...propriate type supplied with the balance Pay attention that supply voltage is compatible with specified technical data Do not use the balance when its cover is opened Do not use the balance in explosi...

Page 8: ...the balance remember the following rules to ensure proper working conditions and user friendly operating setup the balance on an even flat surface leaving necessary room for easy access maintain prop...

Page 9: ...of the balance is in the middle 4 Place tin floor plate 4 and the pan ring 3 in the weighing chamber and gently put on the pan support 2 and finally the pan 1 5 Plug a feeder to the power socket at th...

Page 10: ...or right Storing a tare value does not extend measuring range but only subtracts it from a load placed on the pan To make weight control easier and to avoid range overdrawing the balance is equipped...

Page 11: ...balance a service centre should use calibration weight as stated in Technical Data table or of better accuracy with valid calibration certificate External calibration in verified balance should be pe...

Page 12: ...ess T to choose C_LOAD and calibration weight value Press T to choose CAL_EXt Wait until zeroing process is finished When LOAD communicate put a calibration weight on the pan Wait until calibration pr...

Page 13: ...and press key The beginning of internal calibration is signalised with CAL communicate on the display Internal calibration settings time intervals and temperature changes Press MENU to call functions...

Page 14: ...bel printers Serial port working modes Standard mode The balance sends weighing result after initialising signal from a computer or after pressing key Automatic mode when cooperating with a printer Th...

Page 15: ...0Dh Byte 16 LF 0Ah 2 Automatic mode After stabilisation of each weighing result excluding zero indication the balance sends 3 digit successive measurement number and a weighing result To clear the me...

Page 16: ...lance KAFKA printer KAFKA printer internal switches set up SW 1 SW 2 SW 3 SW 4 SW 5 SW 6 SW 7 SW 8 on off on off off on off off It is possible to use a transmission protocol other then LonG on custome...

Page 17: ...ial port working mode setting Other functions recipe ingredients summing density calculation and other special functions can be enabled as an option on customer request described in additional brochur...

Page 18: ...gend press a key balance indication forced change automatic change 16 Normal weighing When the pan is empty and indication is different than zero press T key Weighing result should be read when the in...

Page 19: ...cation if the pan is empty or if zero indication was acquired by pressing T key Function has options On function is activated OFF function is not activated CorrECt maximum zero flow to be automaticall...

Page 20: ...is advised that single piece weight is not less than one reading unit and sample weight used in first phase is bigger than 100 reading units To leave function press MENU key and then with T key chose...

Page 21: ...232CS Function alows to set RS232C parameters velocity bAud 1200 4800 9600 bits bit 7 8 parity control PArItY 0 1 Odd 0 1 continuous transmition without key 10 times per secund SEnd 0 1 Press MENU to...

Page 22: ...__________________________ 22 21 Date and time setting F dAt Function puts date and time into printout and alows to set actual Function has options dAtE date setting tIME time setting Changing value n...

Page 23: ...ibrate the balance contact nearest service 5 It is forbidden to make any repairs by unauthorised persons 6 To repair the balance please contact our nearest service Error communicates Communicate Possi...

Reviews: