Safety notes 

Please read this manual carefully and completely before you use the device for the first time. The 
device  may  only  be  used  by  qualified  personnel  and  repaired  by  PCE  Instruments  personnel. 
Damage or injuries caused by non-observance of the manual are excluded from our liability and 
not covered by our warranty. 
 

 

The device must only be used as described in this instruction manual. If used otherwise, 
this can cause dangerous situations for the user and damage to the meter. 

 

The instrument may only be used if the environmental conditions (temperature, relative 
humidity, …) are within the ranges stated in the technical specifications. Do not expose 
the device to extreme temperatures, direct sunlight, extreme humidity or moisture. 

 

Do not expose the device to shocks or strong vibrations. 

 

Be careful with rotating objects! Even if they appear motionless in the stroboscopic light, 
the risk of injury is high. 

 

Do not look directly into the flash as this could injure your eyes. 

 

Do not point the stroboscope at other people. Light pulses of more than 5 Hz may cause 
people with photosensitive epilepsy to suffer a seizure. 

 

Do not touch the lamp with bare hands. 

 

The case should only be opened by qualified PCE Instruments personnel. 

 

Never use the instrument when your hands are wet. 

 

You must not make any technical changes to the device. 

 

The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner, 
no abrasives or solvents. 

 

The device must only be used with accessories from PCE Instruments or equivalent. 

 

Before each use, inspect the case for visible damage. If any damage is visible, do not 
use the device. 

 

Do not use the instrument in explosive atmospheres. 

 

The measurement range as stated in the specifications must not be exceeded under 
any circumstances. 

 

Non-observance of the safety notes can cause damage to the device and injuries to 
the user. 

 
We do not assume liability for printing errors or any other mistakes in this manual. 
 
We expressly point to our general guarantee terms which can be found in our general terms of 
business. 
 
If you have any questions please contact PCE Instruments. The contact details can be found at 
the end of this manual. 
 
 
 

 

Summary of Contents for PCE-DSX 20

Page 1: ...Stroboscope User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change 19...

Page 2: ...Front and back 3 4 2 Top and bottom 4 5 Operation 4 5 1 Preparation 4 5 2 Set flash frequency 5 5 3 Rotational speed measurement 5 5 4 External input 6 5 5 Synchronised output trigger output 7 5 6 Mo...

Page 3: ...yes Do not point the stroboscope at other people Light pulses of more than 5 Hz may cause people with photosensitive epilepsy to suffer a seizure Do not touch the lamp with bare hands The case should...

Page 4: ...PM 0 1 of rdg 2 dgt 9999 RPM 1 RPM 35000 RPM 10 RPM Level ext trigger High 2 5 12 V Low 0 8 V Lamp type Xenon flash Flash response time 10 30 s Colour temperature 6500 K Flash output 8 joules Beam ang...

Page 5: ...description 4 1 Front and back Screws protective glass Ext trigger input signal output Xenon flash lamp 230 V AC input Internal external selection key MODE key Key X 2 doubling Key Key 2 halving Key...

Page 6: ...ED Trigger mode LED mSec mode LED Tripod thread 5 Operation 5 1 Preparation Before first use remove the film from the front protective glass and the display Connect the stroboscope to the power supply...

Page 7: ...s for fine adjustment Per keystroke the last digit of the flash frequency is changed by the value 1 Holding the key changes the tens or hundreds of the flash frequency 5 3 Rotational speed measurement...

Page 8: ...cope is signalled by flashing of the display and the flash triggering is set 5 4 1 Rotational speed Select speed with the MODE key As soon as an external signal is present the stroboscope flashes in t...

Page 9: ...e maximum time of use of the stroboscope per measurement should not exceed the following times The pause between measurements should be at least 10 minutes Flash frequency Duration 2000 RPM 4 hours 20...

Page 10: ...pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devic...

Page 11: ...Unit 11 Southpoint Business Park Via Pesciatina 878 B Interno 6 Halkal Merkez Mah Ensign Way Southampton 55010 Loc Gragnano Pehlivan Sok No 6 C Hampshire Capannori Lucca 34303 K k ekmece stanbul Unite...

Reviews: