Specifications 

Function 

Range 

Resolution 

Accuracy 

Flashes / speed 

50 ... 35000 
RPM/FPM 

<1000 PRM: 0.1 RPM 

±(0.05 % of rdg. 
 + 2 dgt.) 

<9999 RPM: 1 RPM 

<35000 RPM: 10 RPM 

Flash frequency 

0.833 ... 583.3 Hz 

<599.9 RPM: 0.001 Hz 

±(0.05 % of rdg. 
 + 2 dgt.) 

<5999 RPM: 0.01 Hz 

<35000 RPM: 0.1 Hz 

Phase shift 

0 ... 359° 

1° 

±(0.1% of rdg. + 2 
dgt.) 

Ext. trigger 

0 ... 1200 ms 

<1000 PRM: 0.1 RPM 

±(0.1% of rdg. + 2 
dgt.) 

<9999 RPM: 1 RPM 

<35000 RPM: 10 RPM 

Level ext. trigger 

High: 2.5 ... 12 V 

Low: <0.8 V 

Lamp type 

Xenon flash 

Flash response time 

10 ... 30 µs 

Colour temperature 

6500 K 

Flash output 

8 joules 

Beam angle 

80 ° 

Power supply 

PCE-DSX 20: 230 V AC 50/60 Hz 

PCE-DSX 20-US: 110 V AC 50/60 Hz 

Power consumption 

240 mA @ 3600 FPM 

Operating conditions 

0 ... 50 °C / 32 ... 122 °F; max. 80 % RH 

Dimensions 

230 x 110 x 150 mm / 9 x 4.3 x 5.9

“ 

Weight 

approx. 1145 g / 2.5 lbs 

 

Delivery scope 

1 x stroboscope PCE-DSX 20 
1 x plug for trigger input / output 
1 x power cable  
1 x user manual 
 

 

Summary of Contents for PCE-DSX 20

Page 1: ...Stroboscope User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change 19...

Page 2: ...Front and back 3 4 2 Top and bottom 4 5 Operation 4 5 1 Preparation 4 5 2 Set flash frequency 5 5 3 Rotational speed measurement 5 5 4 External input 6 5 5 Synchronised output trigger output 7 5 6 Mo...

Page 3: ...yes Do not point the stroboscope at other people Light pulses of more than 5 Hz may cause people with photosensitive epilepsy to suffer a seizure Do not touch the lamp with bare hands The case should...

Page 4: ...PM 0 1 of rdg 2 dgt 9999 RPM 1 RPM 35000 RPM 10 RPM Level ext trigger High 2 5 12 V Low 0 8 V Lamp type Xenon flash Flash response time 10 30 s Colour temperature 6500 K Flash output 8 joules Beam ang...

Page 5: ...description 4 1 Front and back Screws protective glass Ext trigger input signal output Xenon flash lamp 230 V AC input Internal external selection key MODE key Key X 2 doubling Key Key 2 halving Key...

Page 6: ...ED Trigger mode LED mSec mode LED Tripod thread 5 Operation 5 1 Preparation Before first use remove the film from the front protective glass and the display Connect the stroboscope to the power supply...

Page 7: ...s for fine adjustment Per keystroke the last digit of the flash frequency is changed by the value 1 Holding the key changes the tens or hundreds of the flash frequency 5 3 Rotational speed measurement...

Page 8: ...cope is signalled by flashing of the display and the flash triggering is set 5 4 1 Rotational speed Select speed with the MODE key As soon as an external signal is present the stroboscope flashes in t...

Page 9: ...e maximum time of use of the stroboscope per measurement should not exceed the following times The pause between measurements should be at least 10 minutes Flash frequency Duration 2000 RPM 4 hours 20...

Page 10: ...pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devic...

Page 11: ...Unit 11 Southpoint Business Park Via Pesciatina 878 B Interno 6 Halkal Merkez Mah Ensign Way Southampton 55010 Loc Gragnano Pehlivan Sok No 6 C Hampshire Capannori Lucca 34303 K k ekmece stanbul Unite...

Reviews: