© PCE Instruments
6
5.4
External input
•
Connect an external signal cable to the signal input on the rear side. (connector plug is
included in the delivery scope)
•
Switch on the stroboscope via the switch on the back.
•
Use the "Int / Ext Signal" key to select the External option.
•
Within this setting, it is not possible to adjust the flash frequency on the device.
An external trigger signal that is outside the controllable flash frequency of the stroboscope is
signalled by flashing of the display and the flash triggering is set.
5.4.1
Rotational speed
•
Select speed with the "MODE" key.
•
As soon as an external signal is present, the stroboscope flashes in time with the
external signal. The corresponding rotational speed is shown on the display.
5.4.2
Phase shift delay mode (ms/degree)
If the input signal is 360 ° (see sketch), you can delay the flash by up to 359°. A correct setting is
only possible with a stable trigger signal.
•
Use the "MODE" key to select deg or mSec.
•
The flash delay is changed with the "+ / - rotary switch".
The flash frequency is maintained but, depending on the setting, triggered with a
delay.