background image

 

 

 

©  PCE Instruments 

 

5.4 

External input 

 

Connect an external signal cable to the signal input on the rear side. (connector plug is 
included in the delivery scope) 

 

 

 

 

Switch on the stroboscope via the switch on the back. 

 

Use the "Int / Ext Signal" key to select the External option.  

 

Within this setting, it is not possible to adjust the flash frequency on the device. 

An  external  trigger  signal  that  is  outside  the  controllable  flash  frequency  of  the  stroboscope  is 
signalled by flashing of the display and the flash triggering is set. 

5.4.1 

Rotational speed 

 

 

 

Select speed with the "MODE" key. 

 

As  soon  as  an  external  signal  is  present,  the  stroboscope  flashes  in  time  with  the 
external signal. The corresponding rotational speed is shown on the display. 

5.4.2 

Phase shift delay mode (ms/degree) 

If the input signal is 360 ° (see sketch), you can delay the flash by up to 359°. A correct setting is 
only possible with a stable trigger signal. 

 

 

 

 

Use the "MODE" key to select deg or mSec. 

 

The flash delay is changed with the "+ / - rotary switch".  
The flash frequency is maintained but, depending on the setting, triggered with a 
delay. 

 

 

Summary of Contents for PCE-DSX 20

Page 1: ...Stroboscope User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change 19...

Page 2: ...Front and back 3 4 2 Top and bottom 4 5 Operation 4 5 1 Preparation 4 5 2 Set flash frequency 5 5 3 Rotational speed measurement 5 5 4 External input 6 5 5 Synchronised output trigger output 7 5 6 Mo...

Page 3: ...yes Do not point the stroboscope at other people Light pulses of more than 5 Hz may cause people with photosensitive epilepsy to suffer a seizure Do not touch the lamp with bare hands The case should...

Page 4: ...PM 0 1 of rdg 2 dgt 9999 RPM 1 RPM 35000 RPM 10 RPM Level ext trigger High 2 5 12 V Low 0 8 V Lamp type Xenon flash Flash response time 10 30 s Colour temperature 6500 K Flash output 8 joules Beam ang...

Page 5: ...description 4 1 Front and back Screws protective glass Ext trigger input signal output Xenon flash lamp 230 V AC input Internal external selection key MODE key Key X 2 doubling Key Key 2 halving Key...

Page 6: ...ED Trigger mode LED mSec mode LED Tripod thread 5 Operation 5 1 Preparation Before first use remove the film from the front protective glass and the display Connect the stroboscope to the power supply...

Page 7: ...s for fine adjustment Per keystroke the last digit of the flash frequency is changed by the value 1 Holding the key changes the tens or hundreds of the flash frequency 5 3 Rotational speed measurement...

Page 8: ...cope is signalled by flashing of the display and the flash triggering is set 5 4 1 Rotational speed Select speed with the MODE key As soon as an external signal is present the stroboscope flashes in t...

Page 9: ...e maximum time of use of the stroboscope per measurement should not exceed the following times The pause between measurements should be at least 10 minutes Flash frequency Duration 2000 RPM 4 hours 20...

Page 10: ...pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devic...

Page 11: ...Unit 11 Southpoint Business Park Via Pesciatina 878 B Interno 6 Halkal Merkez Mah Ensign Way Southampton 55010 Loc Gragnano Pehlivan Sok No 6 C Hampshire Capannori Lucca 34303 K k ekmece stanbul Unite...

Reviews: