Working with control panel
11/29
When grain is removed from moisture meters, the current values of the moisture
will show zero, but the average values will retain their previous readings (fig. 7). Av-
eraged values can be reset by pressing on them when the measurement channel of
the sensor is empty.
fig 7. Showing average moisture values
Special
mode can be used in order to simulate flow measurement
process in the moisture control system (fig. 8). It allows obtaining an average mois-
ture value for the same product based on the results of several single measurements.
After selection of the product press
button to switch to “Laboratory” mode
(fig. 8).
fig 8. “Laboratory” mode
By default “
Number of measurements
” line should read 4. Press
but-
ton and fill moisture sensor
A
with a portion of grain. Wait for sound signal and the
appearance of figure “1” in
“Conducted measurements”
line. Remove grain from the
sensor and then fill in the sensor with again to see figure “2” after the signal. Repeat
the procedure four times. After the four measurements
“Moisture %”
window would