443B101/443B102
6
Manual 19854 Rev. D
ECN 50523
OUT
SEN TED MEM
MODE LF LPF LCD
2. Using down and right arrow keys, select LF.
3. Press the MENU button.
4. Press the down arrow key until the display
shows:
1.0 Hz
10.0 Hz
Velocity
5. Select the desired setting and press the MENU
button. The display shows:
SELECT UNITS
SI
ENGLISH
If SI is selected, then SI units are displayed.
Select the desired unit and press MENU. If ENGLISH
is selected, the display shows:
XX.XX mV/in/s
X.XXX pC/g
Displacement Measurement
1. Press the MENU button. The display shows:
OUT
SEN TED MEM
MODE LF LPF LCD
2. Select LF and press the menu button. The
display shows the previous setting.
3. Press the up arrow key until the display shows:
1 Hz
10.0 Hz
Displacement
4. Select the appropriate lower frequency and
press the MENU button. The display shows:
SELECT UNITS
SI ENGLISH
5. Select the desired units and press the MENU
button. If ENGLISH was selected the display
shows:
X.XXX mV/mil
X.XXX pC/g
If SI is selected, SI units are displayed.
6. Set the desired output sensitivity and press the
MENU button. The Model 443B is now set up
and calibrated for displacement measurements.
Using the Setup Memory
The 443B has the capability to save and recall up to
five different setups so that the user can easily
switch between frequently used configurations. To
save a setup:
1. Press MENU and move the cursor to the MEM
position.
2. Press MENU again.
3. Move the cursor to SAVE and press MENU.
4. Move the cursor to the number (1-5) of the
setup location you wish to save the current
configuration in.
5. If you decide not to save the setup, move the
cursor to CANCEL.
6. Press MENU again and the unit will then return
to its previous state.
7. To recall a setup, first press MENU and move the
cursor to the MEM position.
8. Press MENU again.
9. Move the cursor to RECALL and press MENU.
10. Move the cursor to the number of the setup
location you wish to recall.
11. If you decide not to recall the setup, move the
cursor to CANCEL.
12. Press MENU again and the unit will reset itself to
the stored configuration.
Setting the LCD Backlight Level
1. Press MENU and select LCD.
2. Press MENU and the display shows:
LCD BACKLIGHTING
3
2
1
Off
3. Select the desired backlight level and press
MENU.
Computer / RS-232 Control
The 443B series provides for remote control of all
functions via an RS-232 interface when used with a
model 441A3X chassis with computer control.
Appendix A gives the setup information as well as
the command set.
Summary of Contents for 441A101
Page 14: ...CHASSIS AND POWER SUPPLY 4 Manual 19680 Rev C ECN 50523 Appendix A Figures...
Page 15: ...CHASSIS AND POWER SUPPLY 5 Manual 19680 Rev C ECN 50523...
Page 63: ...443B101 443B102 43 Manual 19854 Rev D ECN 50523 Appendix B Figures...
Page 64: ...443B101 443B102 44 Manual 19854 Rev D ECN 50523...
Page 65: ...443B101 443B102 45 Manual 19854 Rev D ECN 50523...
Page 66: ...443B101 443B102 46 Manual 19854 Rev D ECN 50523...
Page 67: ...443B101 443B102 47 Manual 19854 Rev D ECN 50523...
Page 68: ...443B101 443B102 48 Manual 19854 Rev D ECN 50523...
Page 75: ......
Page 81: ......
Page 82: ......