![Pavone Systems DAT 1400 Technical Manual Download Page 50](http://html.mh-extra.com/html/pavone-systems/dat-1400/dat-1400_technical-manual_764004050.webp)
Page 48
WEIGHING PARAMETERS
The parameters in this menu permit adjustment of the times for acquisition and updating of the display
and manual or automatic resetting by the transmitter.
uSE
INSTRUMENT OPERATION
Selecting the operation of the instrument. In case of a change from FREE operation to METRIC operation,
to confirm the setting authentication is required through the password of authorised personnel.
Value
Variation
Free
Free operation. [0]
Trade
METRIC instrument operation. [1]
Default: Free
Not1on
STABILITY OF WEIGHT [1303]
This parameter defines the number of divisions needed to consider the weight stable.
A high number of divisions allows the transmitter to quickly detect stability of the weight, which is nee-
ded when executing tare and print commands.
Value
Variation
0
Weight always stable
1
Stability determined quickly
2
Stability determined with medium parameters
3
Stability determined accurately
4
Stability determined with the highest accuracy
Default: 2
AUto-0
AUTOZERO WHEN SWITCHING ON [1304-1305]
This parameter defines the value of maximum weight that can be reset when the instrument is switched on.
This operation corresponds to zero calibration of the system andis executed only if the weight is stable
and below the set value.
Value: from 0 to Capacity.
Default: 0