Page 15
CONFIGURATION PARAMETERS
Through the setting of the parameters listed below, the DAT 100 Full Scale datasheet calibration is
performed. You must complete these steps with the zero calibration described on the next page. The
procedure ensures, in the absence of mechanical problems, a good accuracy of the system (maximum
error <1% FS).
CapaC
CAPACITY OF THE WEIGHING SYSTEM
It defines the value corresponding to the sum of the rated capacity of the
load cells. In case of single load cell systems and “N” fixed supports,
enter the capacity value of the load cell for the total number of sup-
ports. This figure represents the full scale value of the weighing system.
Following the change of the parameter value, the datasheet calibra-
tion of the weight is recalculated.
Values: from 1 to 99999
Unit: the same of that displayed
Default: 10000
SEnst
LOAD CELLS SENSITIVITY
Set the value corresponding to the average of the load cells sensitivity,
in mV/V. The instrument accepts values between 0.5 and 4 mV/V.
If no value is entered, the unit assumes it is 2 mV/V.
Following the change of the sensitivity value, the datasheet tare of
the weight is recalculated.
Values: from 0.5000 to 4.0000 mV/V
Default: 2.0000
dspdJ
DIVISION VALUE
The ratio between the maximum capacity of the system and the
division value is the resolution of the system (number of divisions).
Following the change of the capacity of the system, it is automatically
selected the division value to the best of 5000 divisions.
Following the change of the division value, if the maximum capa-
city does not change, the calibration of the weight is automatically
corrected.
Selectable Values:
0.0001 - 0.0002 - 0.0005
0.001 - 0,002 - 0,005
0.01 - 0.02 - 0.05
0.1 - 0.2 - 0.5
1 -2 - 5
10 - 20 - 50
Default: 1
s1GnL
TESTING THE LOAD CELLS SIGNAL
It’s displayed the signal acquired from the load cells expressed in
mV / V.
Summary of Contents for DAT 100
Page 2: ...Page II ...