INOUT - LOGIC INPUTS AND OUTPUT (DAT 100/A ONLY)
NodE1
SETPOIN 1 OPERATION MODE
Select 4 operation criterias of the SET POINT 1 in sequence:
NET
The relay output is active in Net Weight mode
GROSS
The relay output is active in Gross Weight mode
PEAK
The relay output is active in Peak mode
Default: GROSS
Comparison with net weight, gross weight or peak. In this last case,
the comparison is made with the last peak value acquired, even
when the peak function is not active.
N.O.
The relay 1 is normally open
N.C.
The relay 1 is normally closed
Default N.O.
POS.
The output is operating with positive weight
NEG.
The output is operating with negative weight
Default: POS
NORML
Output 1 is active with unstable weight
STABL
The output is active with stable weight
Default: Norml
hyst1
HYSTERESIS OF THE SET POINT 1
Hysteresis value compared to the SET POINT value
Values from 000 to 999
Default: 2
NodE2
SET POINT 2 OPERATION MODE
Select 4 operation criterias of the SET POINT 2 in sequence:
NET
The relay output is active in Net Weight mode
GROSS
The relay output is active in Gross Weight mode
PEAK
The relay output is active in Peak mode
Default: GROSS
Comparison with net weight, gross weight or peak. In this last case,
the comparison is made with the last peak value acquired, even
when the peak function is not active.
N.O.
The relay 2 is normally open
N.C.
The relay 2 is normally closed
Default N.O.
POS.
The output is operating with positive weight
NEG.
The output is operating with negative weight
Default: POS
NORML
Output 2 is active with unstable weight
STABL
Output 2 is active with stable weight
Default: Norml