![Patton IPLink 2603 Series User Manual Download Page 46](http://html1.mh-extra.com/html/patton/iplink-2603-series/iplink-2603-series_user-manual_4042656046.webp)
4 • Configuring the IPLink Router
Models 2603, 2621, & 2635 High Speed Routers User Guide
46
WAN Port Configuration
Once all options have been entered, save the configuration as follows:
Type system config save then press Enter.
This concludes the T1 interface configuration via CLI go to section “WAN Service Configuration” on page 47
for instructions on router/bridge and WAN service configuration.
Configuring the IPLink Series 2603 for E1 Operation
Web Configuration.
Launch Internet Explorer or similar web browser, type the IP address of the 2603, enter
username
superuser
and password
superuser
. From the main page click on the E1/T1 option > Configuration.
Time Slot Select.
For unframed E1 service (Clear Channel) enter time slots 0-31. For a full framed E1 enter 1-
31, for partially filled E1 enter the range of timeslots using the format for example: 1,2,3,5; or 1-5,10-31. Any
entry for timeslots above 31 will return and invalid selection message.
Line Options:
Choose from Clear Channel E1, Fractional E1, Multi-Frame(CAS) E1, Multi-Frame(CAS) E1
with CRC. Consult with your service provider which option is required.
Line Code:
Choose from AMI or HDB3. Most E1 applications use HDB3
Line Build Out:
Select 120 Ohms if the E1 connection is made via the RJ-48C connector, select 75 Ohm if
the E1 connection is made via the Dual BNC connectors.
FDL Mode:
FDL is a T1 application, therefore select ‘Fdl- none’ for E1 applications.
Clocking Mode:
Options are Internal or Receive Recover Clock (network). In most applications clocking for
the 2603 will be derived from the E1 network, set the unit for Receive Recover unless instructed otherwise by
your service provider.
Idle code:
Options are Enabled or Disabled. When idle code is Enabled, the 2603 inserts idle codes (7E hex)
on unused timeslots. Set this option to Disabled unless instructed otherwise.
Power Down:
Options are Normal and Powerdown. When powered down, the E1 will put high impedance on
the input and output lines to protect the device—set unit to Normal for regular operation.
Summary of Contents for IPLink 2603 Series
Page 8: ...Contents Models 2603 2621 2635 High Speed Routers User Guide 8 ...
Page 14: ...About this guide Models 2603 2621 2635 High Speed Routers User Guide 14 ...
Page 23: ...23 Chapter 2 Product Overview Chapter contents Introduction 24 Applications Overview 25 ...
Page 89: ...89 Chapter 8 Monitoring Status Chapter contents Status LEDs 90 ...
Page 98: ...9 T1 E1 Diagnostics Models 2603 2621 2635 High Speed Routers User Guide 98 Software Upgrades ...
Page 109: ...109 Appendix B Cable Recommendations Chapter contents Ethernet Cable 110 Adapter 110 ...