![Patton CopperLink CL1300 Quick Start Manual Download Page 7](http://html2.mh-extra.com/html/patton/copperlink-cl1300/copperlink-cl1300_quick-start-manual_4043541007.webp)
CopperLink 1300 Quick Start Guide
7
CL1300R Series
The CL1300R comes standard with an AC switching power supply or an internal DC
power converter.
AC power supply.
The CL1300R comes standard with an AC power supply:
•
There is one fuse in the equipment rated at 250V, 500 mA, 2 sec.
•
Rated voltage: 5 VDC
•
Rated current: 1 A DC
•
Output from power supply: 5 VDC, 2A
•
Input to power supply: universal input 100–240 VAC 50/60 Hz 0.3A
Do the following:
1.
Plug the AC switching power supply (see
) terminal block plug into the
CL1300R terminal block (see
2.
If it hasn’t already been done, slide the AC plug that came with the AC switching
power supply (see
) onto the AC switching power supply.
3.
Connect the AC plug end of the AC switching power supply into an AC power out-
let.
Figure 7.
AC Switching Power Supply with Terminal Block Plug