CopperLink 1300 Quick Start Guide
3
Figure 1.
CL1300 Ethernet Extender rear panel
Figure 2.
CL1300R Ethernet Extender front panel
Connect the Line Interface
To function properly, the CL1300 must be connected using a twisted-pair, uncondi-
tioned, dry, metal wire, between 19 (0.9mm) and 26 AWG (0.4mm). Leased circuits that
run through signal equalization equipment are not acceptable.
The Ethernet Extender is equipped with a RJ-45 interface jack (
Line
), which conforms
to the T568B standard. As such, any standard Category 5e cable can be used to directly
connect two extenders. Depending on the extender model, it will have a two-wire or
four-wire interface.
Observe the signal/pin relationship on the CL1300’s
Line
interface jack for each pair in