5.0  OPERATION

Once you have configured each Model 1065 Series unit properly

and connected the twisted pair and RS-232 cables  (see Section 4.0),
you are ready to operate the units.  This section describes reading the
LED status monitors, powering-up and using the built-in V.52 and V.54
test modes.

5.1  LED STATUS MONITORS

The Model 1065 Series features seven front panel status LEDs that

indicate the condition of the modem and communication link.  Figure 5
shows the front panel location of each LED.  Following Figure 6 is a
description of each LED's function.

5.1.1  The “TD” and “RD” Indicators

The Power LED glows green to signal power present. The “TD” and

“RD” indicators blink green with data activity. Off indicates a low RS-
232 logic level, green indicates a high RS-232 logic level.  Note:  RS-
232 devices idle in a 

low state, so the LED will be off if the connections

are correct and the RS-232 device is in an idle state.

5.1.2  The “RTS” and “CD” Indicators

The “RTS” and “CD” indicators are monocolor and will be off for a

“low” signal or green for a “high” signal.  RTS lights for an incoming
signal on RS-232 pin 4.  CD lights for an incoming signal on the line
side, and the resulting output signal on RS-232 pin 8.

5.1.3  The “Test” Indicator

The yellow“Test” LED indicates that V.52 or V.54 tests are running.

5.1.4  The “Error” Indicators

The “Error” indicator LED has two functions:

A.  When the 1065 unit is in test mode (green “Test” LED is lit), the

error LED glows red when bit errors occur.  

B.  When not in test mode (green “Test” LED is off), the error LED

is used to indicate an RTS streaming condition.  (See Section 5.2) for
information on the anti-streaming circuitry.  

5.2  ANTI-STREAMING ERROR INDICATOR

When not in test mode (green “Test” LED is off), the front panel

“Error” LED is used to indicate a streaming error.  When the Model
1065s’ anti-streaming circuitry is enabled, the RTS signal from the DTE
is timer controlled.  The timer begins to count when the DTE raises
RTS.  If the time period that RTS remains high exceeds the preset time
out period, the anti-stream circuit will force RTS low.  The “Error” LED
will light red, indicating a streaming condition (RTS continually on).
This feature prevents a malfunctioning terminal from tying-up a com-
puter port in a multi-drop or polling environment.  When the DTE drops
RTS, the anti-streaming timer is automatically reset and the front panel
“Error” LED turns off.  The time out period is DIP switch selectable for
12.5 or 50 seconds.

Figure 6.  Model 1065 front panel.

Model 1065 Industrial Short Range Modem

TX

Power

RX

RTS

CD

Error

Test

V.54 Test

Modes

511 -

511E -

- Remote

- Normal

- Local

Summary of Contents for Model 1065

Page 1: ...EL L 1 10 06 65 5 Industrial Synchronous Asynchronous Short Range Modem SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1065 A Doc 058041UA Revised 08 11 99 An ISO...

Page 2: ...nstalled and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and tele vision reception If the Model 1065 does cause interference to radi...

Page 3: ...against data loss due to ground potential differences and Silicon Avalanche Diode surge protection to guard against data line transients The Model 1065 features V 52 compliant bit error rate pattern...

Page 4: ...it clock Off On Receive recover clock On Off External transmit clock Switch S1 7 Asynchronous Synchronous Mode The setting for switch S1 7 determines whether the Model 1065 Series is in asynchronous o...

Page 5: ...ven frequency level the Model 1065 Series will tolerate S2 3 Setting Off 2 5 to 1 On 2 5 to 2 3 Switches S2 4 and S2 5 RTS CTS Delay The combined settings for switches S2 4 and S2 5 determine the amou...

Page 6: ...h S3 3 to select the timing mode of the 1065 To oper ate the 1065 at 16 32 or 64kbps set S3 3 to the On position To select any other DTE rate set Switch S3 3 Off S3 3 Setting On 16 32 or 64kbps Off 1...

Page 7: ...logies the twisted pair wire must be 19 26 AWG dry unconditioned metallic wire see Appendix C for wire recommendations Dial up analog circuits such as those used with a standard Hayes type modem are n...

Page 8: ...d a pair of Model 1065s for each circuit one at each end of the two pair cable In two pair multi point applications you will need three or more Model 1065 units These can be connected using a star top...

Page 9: ...Pair Connection The Model 1065 supports multipoint applications using a star topol ogy Maximum distance between the units will vary based upon the number of drops data rate wire gauge etc Call Patton...

Page 10: ...pin 8 5 1 3 The Test Indicator The yellow Test LED indicates that V 52 or V 54 tests are running 5 1 4 The Error Indicators The Error indicator LED has two functions A When the 1065 unit is in test m...

Page 11: ...4 2 Remote Digital Loopback RDL The Remote Digital Loopback RDL test checks the performance of both the local and remote Model 1065s and the communication link between them Any characters sent to the...

Page 12: ...antly ON or controlled by RTS RTS CTS delay set to no delay 7 or 53 ms Applications Point to point or multi point Indicators Mono color LED indicators for TD RD RTS DCD single LED indicators for Power...

Page 13: ...suitable for all our Short Range Modems however distances may vary from those published in our catalog Resistance will also affect distance but not functionality Wire should be 26 AWG 4mm or larger s...

Reviews: