Switch S3-5:  RS-232 Initiation of Local Loopback Test

The setting for switch S3-5 determines whether or not the Model

1065 local analog loopback test can be initiated by raising pin 18 on
the RS-232 interface.

S3-5

Setting

On

RS-232 initiation enabled

Off

RS-232 initiation disabled

Switch S3-6:  RS-232 Initiation of Remote Loopback Test

The setting for switch S3-6 determines whether or not the Model

1065 remote digital loopback test can be initiated by raising pin 21 on
the RS-232 interface.

S3-6

Setting

On

RS-232 initiation enabled

Off

RS-232 initiation disabled

Switches S3-7 and S3-8:  Anti-stream Control

Switches S3-7 and S3-8 are set in combination to determine the

time out period for the Model 1065 Series’ anti-stream control timer.

S3-7

S3-8

Setting

Off

Off

Disabled

Off

On

12.5 seconds

On

Off

50.0 seconds

On

On

12.5 seconds

4.0  INSTALLATION

The Model 1065 operates in four twisted pair topologies:  

2-wire/point-to-point, 2-wire/multipoint, 4-wire/point-to-point, and 
4-wire/multipoint.  In each of these topologies, the twisted pair wire
must be 19 - 26 AWG "dry", unconditioned metallic wire (see Appendix
C for wire recommendations).  Dial-up analog circuits, such as those
used with a standard Hayes-type modem, are not acceptable.  The
twisted pair may be shielded or unshielded.  Both types yield favorable
results.

The Model 1065 offers an RJ-45 jack for its twisted pair line con-

nection.  Figure 4 (below) shows the location of these interfaces on the
rear panel of the Model 1065 Series.  Connect the wire to each Model
1065 Series as described in the instructions that follow the illustration.
The “+” and “-” indicators are for reference only.  

4.1  TWO-WIRE INSTALLATION

When communicating over a single twisted pair circuit, the Model

1065 operates half duplex:  that is, it transmits in only one direction at
a time.  This method of operation is effective for both point-to-point and
multipoint applications.

In single pair point-to-point applications, you will need a pair of

Model 1065s for each circuit—one at each end of the single pair wire.
In single-pair multipoint applications you will need three or more Model
1065 units. These can be connected using a star topology, although a
daisy chain topology is usually used.

Figure 4. Model 1065 rear panel.

Summary of Contents for Model 1065

Page 1: ...EL L 1 10 06 65 5 Industrial Synchronous Asynchronous Short Range Modem SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1065 A Doc 058041UA Revised 08 11 99 An ISO...

Page 2: ...nstalled and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and tele vision reception If the Model 1065 does cause interference to radi...

Page 3: ...against data loss due to ground potential differences and Silicon Avalanche Diode surge protection to guard against data line transients The Model 1065 features V 52 compliant bit error rate pattern...

Page 4: ...it clock Off On Receive recover clock On Off External transmit clock Switch S1 7 Asynchronous Synchronous Mode The setting for switch S1 7 determines whether the Model 1065 Series is in asynchronous o...

Page 5: ...ven frequency level the Model 1065 Series will tolerate S2 3 Setting Off 2 5 to 1 On 2 5 to 2 3 Switches S2 4 and S2 5 RTS CTS Delay The combined settings for switches S2 4 and S2 5 determine the amou...

Page 6: ...h S3 3 to select the timing mode of the 1065 To oper ate the 1065 at 16 32 or 64kbps set S3 3 to the On position To select any other DTE rate set Switch S3 3 Off S3 3 Setting On 16 32 or 64kbps Off 1...

Page 7: ...logies the twisted pair wire must be 19 26 AWG dry unconditioned metallic wire see Appendix C for wire recommendations Dial up analog circuits such as those used with a standard Hayes type modem are n...

Page 8: ...d a pair of Model 1065s for each circuit one at each end of the two pair cable In two pair multi point applications you will need three or more Model 1065 units These can be connected using a star top...

Page 9: ...Pair Connection The Model 1065 supports multipoint applications using a star topol ogy Maximum distance between the units will vary based upon the number of drops data rate wire gauge etc Call Patton...

Page 10: ...pin 8 5 1 3 The Test Indicator The yellow Test LED indicates that V 52 or V 54 tests are running 5 1 4 The Error Indicators The Error indicator LED has two functions A When the 1065 unit is in test m...

Page 11: ...4 2 Remote Digital Loopback RDL The Remote Digital Loopback RDL test checks the performance of both the local and remote Model 1065s and the communication link between them Any characters sent to the...

Page 12: ...antly ON or controlled by RTS RTS CTS delay set to no delay 7 or 53 ms Applications Point to point or multi point Indicators Mono color LED indicators for TD RD RTS DCD single LED indicators for Power...

Page 13: ...suitable for all our Short Range Modems however distances may vary from those published in our catalog Resistance will also affect distance but not functionality Wire should be 26 AWG 4mm or larger s...

Reviews: