background image

1.0  WARRANTY INFORMATION 

Patton Electronics

warrants all Model 2036 and 2037

components to be free from defects, and will

at our option

repair or

replace the products should they fail within one year from the first date
of shipment.

This warranty is limited to defects in workmanship or materials, and

does not cover customer damage, abuse or unauthorized modification.
If these products fail or do not perform as warranted, your sole recourse
shall be repair or replacement as described above.  Under no condition
shall

Patton Electronics

be liable for any damages incurred by the use

of these products.  These damages include, but are not limited to, the
following:  lost profits, lost savings and incidental or consequential
damages arising from the use of or inability to use this product.  

Patton

Electronics

specifically disclaims all other warranties, expressed or

implied, and the installation or use of this product shall be deemed an
acceptance of these terms by the user. 

1.1  RADIO AND TV INTERFERENCE

The Model 2036 and Model 2037 generate and use radio

frequency energy, and if not installed and used properly

that is, in

strict accordance with the manufacturer's instructions

may cause

interference to radio and television reception.  They have been tested
and found to comply with the limits for Class A computing devices in
accordance with the specifications in Subpart J of Part 15 of FCC rules,
which are designed to provide reasonable protection from such
interference in a commercial installation.  However, there is no
guarantee that interference will not occur in a particular installation.  If
they do cause interference to radio or television reception, which can
be determined by disconnecting the RS-232 interface, the user is
encouraged to try to correct the interference by one or more of the
following measures:  moving the computing equipment away from the
receiver, re-orienting the receiving antenna and/or plugging the
receiving equipment into a different AC outlet (such that the computing
equipment and receiver are on different branches).

1.2  CE NOTICE

The CE symbol on your Patton Electronics equipment indicates

that it is in compliance with the Electromagnetic Compatibility (EMC)
directive and the Low Voltage Directive (LVD) of the Union European
(EU).  A Certificate of Compliance is available by contacting Technical
Support.

1

APPENDIX D

PATTON MODEL 2036 BLOCK DIAGRAM 

12

PATTON ELECTRONICS

Title

Size

REV

A

Date:              October 26, 1993                             Sheet         1          of           1

Document Number

102031BA

MODEL 2036 – PARALLEL/SERIAL CONVERTER

A

SERIAL

INTERFACE

DB-25

CONNECTOR

PARALLEL

INTERFACE

CENTRONICS

CONNECTOR

DSR

RTS

DCD

DTR

CTS

RD

TD

GND

6

4

8

20

5

3

2

7

DATA BIT 1

DATA BIT 2

DATA BIT 3

DATA BIT 4

DATA BIT 5

DATA BIT 6

DATA BIT 7

DATA BIT 8

2

3

4

5

6

7

8

9

1

10

11

12

13

15

STROBE

ACKNOWLEDGE

BUSY

PAPER END

SELECT

ERROR

GROUND

CONTROL

PARALLEL

AND

SERIAL

PROCESSOR

DCE/DTE

DETECTOR

STATUS

LED

100K

PULL UP

NETWORK

16-30.33.36

DIP SWITCH

SETTINGS FOR

RATE/LENGTH/PARTY

POWER

SUPPLY

8

3

2

20

6

4

5

9

+VIN

CTS

RTS

DSR

DTR

TD

RD

DCD

+V

–V

REGULATOR

WITH

RESET

MONITOR

+5V

RESET

Summary of Contents for 2036

Page 1: ...E 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2036 C Doc 102061U Rev D Revised 1 22 08 MODEL 2036 and 2037 Parallel to Serial Serial to Parallel Interface Converters An ISO...

Page 2: ...and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television reception They have been tested and found to co...

Page 3: ......

Page 4: ...el to Serial Converter automatically convert RS 232 serial data to parallel data format or vice versa Incorporating advanced microprocessor technology the Model 2036 and 2037 automatically sense and s...

Page 5: ......

Page 6: ...ow control Switch 2 Enable Disable LED Indicator The setting for Switch 2 determines whether the LED indicator is enabled or disabled 5 Flow Control SW1 Hardware OFF Software ON LED SW2 Enabled ON Dis...

Page 7: ......

Page 8: ...ches just plug your converter in to a standard cable and you re ready to go Figure 3 illustrates the proper connections for the Model 2036 and 2037 If you have special ordered a non standard connector...

Page 9: ......

Page 10: ...600 19200 38400 57600 and 115200 bps LED LED displays status and operating condition Power Supply Uses power from RS 232 interface 9Vdc maximum typical current 20mA Typical maximum power consumption 1...

Page 11: ......

Page 12: ...ECTIONS 11 Converter Serial Port Serial Data Serial Software Serial Hardware Function Connected Flow Ctrl Signal Flow Ctrl Signal XON XOFF DTR CTS DSR Serial to Parallel DTE TD RD CTS DSR Serial to Pa...

Page 13: ......

Page 14: ...DTR CTS RD TD GND 6 4 8 20 5 3 2 7 DATA BIT 1 DATA BIT 2 DATA BIT 3 DATA BIT 4 DATA BIT 5 DATA BIT 6 DATA BIT 7 DATA BIT 8 2 3 4 5 6 7 8 9 1 10 11 12 13 15 STROBE ACKNOWLEDGE BUSY PAPER END SELECT ER...

Page 15: ......

Page 16: ......

Reviews: