PATTON MODEL 2036 AND 2037 SPECIFICATIONS

Interface: 

Asynchronous., RS-232C compatible

Connectors:

(Model 2036)
Serial: DB-25 male or female; 
Parallel:  Centronics 36 pin male  
(Model 2037)
Serial: DB-25 female;   
Parallel: DB-25 male or female 

Data Rates:

1200, 2400, 4800, 9600, 19200, 38400, 
57600, and 115200 bps

LED:  

LED displays status and operating condition

Power Supply: 

Uses power from RS-232 interface; 9Vdc 
maximum typical current = 20mA; Typical 
maximum power consumption = 100mW @ 
5V (20mA)

Data Format: 

7 or 8 data bits; 1 or 2 stop bits; even, odd 
or no parity

Temperature Range:

0-60

°

C (32-140

°

F)

Altitude:  

0-10,000 feet

Humidity:  

5 to 95% noncondensing

Dimensions: 

3.37” x 2.43” x 0.76” (Model 2036); 
3.13” x 2.12” x 0.73” (Model 2037)

Weight:  

2 oz. (56.8 grams)

9

3.0  CONFIGURATION

The Model 2036 and 2037 are simple to install and designed for

excellent reliability.  The following instructions will help you set up and
install your converter properly.  If you have any questions, please call
Patton Technical Support at (301) 975-1007.

3.1  CONFIGURATION SWITCHES

The Model 2036 and 2037 each use a set of eight external DIP

switches (see Figure 1) that allow configuration to a wide range of
applications.  Because all eight switches are in one externally
accessible DIP switch package, there is no need to open the case for
configuration.  The configuration switches allow you to select data
rates, parity, word length and flow control selection.  The following
section describes all switch locations, positions and functions.

The Model 2036 and 2037 each use a 

miniature

configuration

switch package.  To configure your unit, use a small screwdriver and
gently push each switch to its proper setting.  The ON and OFF
positions are shown in Figure 2.  Default settings for the DIP switches
are shown in the table on the following page.  Detailed settings follow
the table.

4

Figure 1. 

The location of the configuration switches:  

the Model 2036 (left) and the Model 2037 (right)

Figure 2. 

The miniature configuration switch package

OFF

1 2 3 4 5 6 7 8

DHS-8

OFF

1 2 3 4 5 6 7 8

DHS-8

OFF

1 2 3 4 5 6 7 8

DHS-8

Configuration

Switches

Summary of Contents for 2036

Page 1: ...E 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2036 C Doc 102061U Rev D Revised 1 22 08 MODEL 2036 and 2037 Parallel to Serial Serial to Parallel Interface Converters An ISO...

Page 2: ...and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television reception They have been tested and found to co...

Page 3: ......

Page 4: ...el to Serial Converter automatically convert RS 232 serial data to parallel data format or vice versa Incorporating advanced microprocessor technology the Model 2036 and 2037 automatically sense and s...

Page 5: ......

Page 6: ...ow control Switch 2 Enable Disable LED Indicator The setting for Switch 2 determines whether the LED indicator is enabled or disabled 5 Flow Control SW1 Hardware OFF Software ON LED SW2 Enabled ON Dis...

Page 7: ......

Page 8: ...ches just plug your converter in to a standard cable and you re ready to go Figure 3 illustrates the proper connections for the Model 2036 and 2037 If you have special ordered a non standard connector...

Page 9: ......

Page 10: ...600 19200 38400 57600 and 115200 bps LED LED displays status and operating condition Power Supply Uses power from RS 232 interface 9Vdc maximum typical current 20mA Typical maximum power consumption 1...

Page 11: ......

Page 12: ...ECTIONS 11 Converter Serial Port Serial Data Serial Software Serial Hardware Function Connected Flow Ctrl Signal Flow Ctrl Signal XON XOFF DTR CTS DSR Serial to Parallel DTE TD RD CTS DSR Serial to Pa...

Page 13: ......

Page 14: ...DTR CTS RD TD GND 6 4 8 20 5 3 2 7 DATA BIT 1 DATA BIT 2 DATA BIT 3 DATA BIT 4 DATA BIT 5 DATA BIT 6 DATA BIT 7 DATA BIT 8 2 3 4 5 6 7 8 9 1 10 11 12 13 15 STROBE ACKNOWLEDGE BUSY PAPER END SELECT ER...

Page 15: ......

Page 16: ......

Reviews: