Switch S1-8: Response to Remote Loop Request
Use Switch S1-8 to allow the Model 1092ARC to enter the Remote
Digital Loopback diagnostic test when requested to do so by the far end
modem. For example, when Switch S1-8 is set to “ON”, it will enter
RDL mode (See Section 5.2.2) when requested to do so by the remote
modem.
S1-8
Setting
On
Response to RDL Request Enabled
Off
Response to RDL Request Disabled
3.1.3 Configuration Switch Set “S2” - Management Port Address
If the address is 0 (all ON positions ON S2), then the unit will run
completely from its' dip-switch configuration. This can be useful for
testing circuits independently of the management system.
In order to use the SNMP or control port management, an address
is required. If an address is placed on the switch, the unit will boot from
its stored flash configuration. It begins looking for POLL commands
from the Model 1001MC (SNMP management mode).
Switch S2 allows an 7 bit address to be assigned to a link. The
following rules apply to setting the address. Bit S2-1 is the least
significant bit. A bit set to "ON" is considered a "0". A bit set to "OFF" is
considered a "1". Patton Electronics suggests that you set your
addresses starting with address 1 at the far left of your rack (farthest
away from the power supplies) and increment the numbers by one as
you go from left to right. Setting the addresses in this manner will make
configuration easier as you start using the web page management. An
example of this is shown in table A-1.
10
Switch S1-3: Data Set Ready During Local Line Loopback Test
Use Switch S1-3 to control the behavior of the DSR signal at the
EIA interface during the local line loopback test.
S1-3
Setting
Description
On
Enabled
DSR is on during local
line loop (default)
Off
Disabled
DSR is off during local
line loop
Switches S1-4: Management Setting
When setting the SNMP Management, the DTE rate switches (S1-
1, S1-2, and S2-1) are also needed to be at the ON position. Therefore,
to set a 1092A unit SNMP management mode, the following switches
have to be at the ON position, S1-1, S1-2, S2-1, and S1-4.
Use Switch S1-4 to configure the 1092ARC’s management setting.
S1-3
Setting
Description
On
SNMP Management
Using Netlink
Management System
Off Control Port Management
Using VT100 Control
Port Management
Switches S1-6 and S1-7: Transmit Clock Source
Use Switches S1-6 and S1-7 to configure the 1092ARC for
internal, external, or receive recover clock mode.
S1-6
S1-7
Setting
Description
On
On
Internal
Transmit Clock
derived internally
Off
On
External
Transmit Clock
derived from the
terminal interface
On
Off
Receive Recover
Transmit clock derived
from the received line
signal
Off
Off
hardware reset
Reset to use hardware
switches for
configuration
9