APPENDIX A
PATTON ELECTRONICS MODEL 1095RC
FACTORY REPLACEMENT PARTS
AND ACCESSORIES
Patton Model #
Description
1001RPEM-RAC .................120/240V Rear Power Entry Module
1001RPSM-RUI...................120/240V Front Power Supply Module
1001RPEM-RDC.................DC Rear Power Entry Module
1001RPSM-R48A................48V Front Power Supply Module
1001R14P ...........................Rack 14 Slot 2U Chassis Only
1001R14P/R48V .................Rack 14 Slot 2U w/Dual Universal
Input 48VDC Power Supplies
1001R14P/RUIA..................Rack 14 Slot 2U w/Dual Universal
Input 90-260VAC Power Supplies
European Power Cord
1001R14P/RUIC .................Rack 14 Slot 2U w/Dual Universal
Input 90-260VAC Power Supplies
Austrialia Power Cord
1001R14P/RUID .................Rack 14 Slot 2U w/Dual Universal
Input 90-260VAC Power Supplies
UK Power Cord
1001R14P/RUIG .................Rack 14 Slot 2U w/Dual Universal
Input 90-260VAC Power Supplies
India Power Cord
1001R14P/RUIK..................Rack 14 Slot 2U w/Dual Universal
Input 90-260VAC Power Supplies
US Power Cord
1001RCM12545 ..................DB-25/RJ-45 Rear Card
1001RCM125TB .................DB-25/TB Rear Card
1001RCM13445 ..................M/34/RJ-45 Rear Card
1001RCM134TB .................M/34/TB Rear Card
1001RCM11545 ..................DB-15/RJ-45 Rear Card
1001RCM115TB..................DB-15/TB Rear Card
1001MC...............................Management Card
IM2RC/F..............................64K/G703 Rear Card
IM2RC/B..............................RS-530 Interface Rear Card
IM2RC/D .............................X.21 Interface Rear Card
1180RC DB .........................V.35 Daughter Board
0516FPB1 ...........................Single Width Blank Front Panel
0516FPB4 ...........................4-Wide Blank Front Panel
0516RPB1...........................Single Width Blank Rear Panel
0516RPB4...........................4-Wide Blank Rear Panel
056S1..................................Set of 16 #4 pan head screws/washers
10-25M/35M-1.....................Cable, 6 ft, DB-25 male to M/34 male
1010-10 ...............................Terminal Block, 2 Position, Male
07M1092ARC......................User Manual
34
1.
Activate RDL. This may be done in three ways:
- Move the front panel toggle switch to the Left to “Remote”.
- Raise the RDL signal on the interface (see Appendix C).
- Set Remote Loopback from the VT100 screen.
2.
Perform a V.52 BER test as described in
Section 5.2.3. If the
BER test equipment indicates a fault, and the Local Line
Loopback test was successful for both Model 1092ARCs, you
may have a problem with the twisted pair line between the
modems. You should then check the twisted pair line for
proper connections and continuity.
5.2.3 V.52 (BER) Test Pattern Generator
To use the V.52 BER tests in conjunction with the Remote Digital
Loopback tests* (or with Local Line Loopback tests), follow these
instructions:
1.
Locate the “511/511E” toggle switch on the front panel of the
1092ARC and move it to the left. This activates the V.52 BER
test mode and transmits a “511” test pattern into the loop. If
any errors are present, the local modem’s red “ER” LED will
blink sporadically.
2. If the above test indicates no errors are present, move the
V.52 toggle switch to the right, activating the “511/E” test with
errors present. If the test is working properly, the local
modem's red “ER” LED will blink approximately once per
second. A successful “511/E” test will confirm that the link is
in place, and that the Model 1092ARC’s built-in “511”
generator and detector are working properly.
33
Note: Remote Loopback cannot be activated until
approximately 45 seconds after the two modems have
linked to each other.