VIII.  Preventative Maintenance  

 

Daily 

1. Ensure the Voltage and Amperage conform to the 

nameplate. Voltage must be within 10% of nameplate 
nominal voltage 

2.  Check if the water flow is normal. 

Monthly  

Maintenance is recommended when the insulation reading is 
lower than 10M

. Replace new motor immediately when 

insulation is lower than 1M

 

Annual 

Inspecting of Lubricant: 

  The pump should be checked every 3000 hours or 12 

months. (whichever comes first) 

PS: Loosen the oil plug screw and check the color of the 
lubricant. If the lubricant is non-translucent, please change 
the mechanical seal and the lubricant immediately. Apply 
adhesive before resecuring the oil plug screw to 
strengthen the screw against leakage.  

Biennial 1. 

Replacing 

Lubricant: 

 

   The lubricant should be replaced every 4500 hours or 

24 months. (whichever comes first) 

2.  Change mechanical seal. Inspecting and replacing the 

mechanical seal. Only qualified mechanics with proper 
tools and knowledge should be attempting to service 
this pump or contact our authorized local dealers or 
Teral for such services.  

Every 2 – 5 
years 

1.  During the typical operating cycle, it is recommended to 

have the pump overhauled and inspected periodically.  
This preventative maintenance activity can extend the 
pump operating life cycle. 

2.  Please contact your authorized local dealers of Teral. 

 

 

 

 