WARNING
Accidental starting of the pump can cause severe injury or death.
It is absolutely essential that the rotation of the pump be checked. All the pumps
covered in this manual turn clockwise as viewed from the motor end.
This pump comes with a built in motor protector. In the event of a current overload
or overheating, the pump will stop automatically to protect the motor. After the motor
cools down, the motor protector will automatically reset and the pump can be used
again.
If the motor protector trips frequently, check for the cause. It could be due to
impeller blockage, wrong/low voltage, etc…
For Automatic operation, the pump must stop before the water level reaches Pump
Minimum Water Level.(W.M.L.)
VI. MAINTENANCE
If the pump must be disassembled for repair, please contact the Teral Sales Office or an
Authorized Dealer in your area.
WARNING
Accidental starting of the pump can cause severe injury or death.
ALWAYS
,
disconnect the electrical power before examining/working on the pump. For heavy
parts, use a hoist lift to avoid injury
.
CAUTIONS
Disassembling the pump or modifying the pump will void manufacturer warranty.
ALWAYS
,
check that the voltage and amperage readings are in line with the nameplate of the pump.
Check if the water low is normal.
STORAGE:
NOTICE
If the pump will not be used for a long period of time, wash the pump under tap water
removing any debris. Allow the pump to dry and then store indoors. Before, reinstalling
perform a test run to ensure it is operating correctly and within the parameters stated on the
nameplate