background image

Page

 

11

 

of 16 HPS 848 R.2 

Installer Section

 

SET-UP PROGRAMMABLE FUNTION         

It’s possible to modify the function

s written in this table, the functions are valid for 

LIST 35

To  set/unset  them,  alarm  has  to  be  disarmed  and  driver  door  opened,  press  the  programming 
button  many  times  as  the  number  of  the  function  to  set/unset.

 

The  function  will  be  set  if  it  was 

unset and will be unset if it was set.

 

1 beep, 1 blinker flash and 1 LED flash. 

 The function is set. 

2 beeps, 2 blinker flashes and 2 LED flashes. 

The function is unset.  

 

N° Function and 

initial state

 

FUNCIONS

 

DESCRIPTION

 

 

F. 2 

OFF 

LEARNING WIRELESS SIREN 

The  Patrolline  wireless  sirens  must  be  learned  by  the  alarm  in  order  to  work. 

Both siren and alarm must be in the learning condition. 

Alarm  side:

  enter  in  the  programming  procedure  (2  button  presses),  the  LED  flashes 

quickly. Within 30 seconds set the siren in the learning procedure. 

Siren  side:

  enter  in  the  programming  procedure  grounding  10  times  the  BROWN  siren 

wire  (hood  input),  the  siren  emits  a  series  of  beeps  until  it  is  detected  by  the  alarm 
(beeps became more frequent). 
The learning procedure can end too by grounding again the hood input, so 

it’s better to 

disconnect the hood wire (if used) to enter in the procedure. 

Warning:

 once the alarm has been learned, every time that the system is armed, alarm 

checks  the  presence  of  the  siren  expecting  a  transmission  receiving,  so  if  you  need  to 
remove the siren, you have to erase the siren or disable the "beacon" communication by 
setting the function 29. 

Erasing the siren.

 Enter in the learning procedure, when the LED starts flashing quickly, 

press again for 5 seconds the pushbutton until 1 blinker flash and 1 beep. Siren is erased.

 

F. 3 

OFF 

HPA975 Magnetic sensors learning in the ZONE n°1 

Area 1 is not temporary disabling by the remote control. 

-

 

Push the programming button for 3 times, the LED flashes quickly; 

-

 

During the LED flashing turn ON the magnetic sensor to learn it; 

-

 

The correct learning is indicated by a beep, a flash lamp and the 1 sec. LED ON. 

Repeat the procedure for each magnetic sensor to learn. 
The procedure can stop after 30 seconds from the last learned device or after turned ON 
the ignition key.  The maximum number of the devices accepted into the 

area 1 is 24. 

Erasing all zone1 sensors.

 Enter in the learning procedure, when the LED starts flashing 

quickly, press for 5 seconds the button until a beep, a flash lamp and the 1 sec. LED ON. 

F. 4 

OFF 

HPA975 Magnetic sensors learning in the ZONE n°2

 

Area 2 is temporary disabling by the remote control. 

-

 

Push the programming button for 4 times, the LED flashes quickly; 

-

 

During the LED flashing turn ON the magnetic sensor to learn it; 

-

 

The correct learning is indicated by a beep, a flash lamp and the 1 sec. LED ON. 

Repeat the procedure for each magnetic sensor to learn. 
The procedure can stop after 30 seconds from the last learned device or after ignition ON.  
The maximum number of the devices accepted into the 

area 2 is 8.  

Erasing all zone2 sensors.

 Enter in the learning procedure, when the LED starts flashing 

quickly, press for 5 seconds the button until a beep, a flash lamp and the 1 sec. LED ON. 

 

 

 

Summary of Contents for HPS 848R

Page 1: ...n unit Each update adds new vehicles while maintaining compatibility with earlier In the box there is a summary of those codes but you may want to download from the site www patrolline it the updated...

Page 2: ...both in synchronous with the original ones or independently for greater safety see programmable functions n 5 and n 26 HPS 977 With the addition of a transponder is possible to manage transparently th...

Page 3: ...it turn on the key PRESSING THE TRUNK RELEASE OF ORIGINAL REMOTE CONTROL If the device is armed the triggers for trunk opening shock and ultrasonic sensor will be inhibited to permit the access the t...

Page 4: ...opening of the door until turn on the key BUTTON 1 2 Exclusion zone 2 sensors Simultaneously pressing buttons 1 and 2 after 10 sec of the insertion system for excluding the alarm signal of the program...

Page 5: ...10km h speed threshold and if the system cannot detect the recognition after 40 seconds the alarm system actives the siren sound for 20 seconds pre alarm form now if the vehicle speed falls below the...

Page 6: ...when the trunk will physical open the ultrasonic sensor and shock sensor will be disarmed to avoid the alarm trigger These protections will be armed again when the trunk will physical close These func...

Page 7: ...when the alarm is armed via the ignition key as per the procedure detailed below 1 Turn the ignition key ON OFF as many times as per the first digit e g 1 in case of factory setting The LED is illumi...

Page 8: ...dashboard will flash twice To remind that the Valet function is active the LED on the dashboard will flash twice at any time one turns on the ignition key Deactivation Compose using the ignition key...

Page 9: ...ive WHITE GREEN 13 Negative output for confort 100mA GREEN 14 BLUE 4 BROWN 7 BROWN 7 out negative module 100mA ORANGE 8 2 out positive fixe PINK 3 Negative input for ultrasonic free 1 2 3 4 Negative o...

Page 10: ...pened F 5A Battery Negative Battery positive Description The HPS 98 siren operating with 2 4 GHz wireless technology Once learned to an alarm unit it will become like a normal wired siren adding addit...

Page 11: ...beacon communication by setting the function 29 Erasing the siren Enter in the learning procedure when the LED starts flashing quickly press again for 5 seconds the pushbutton until 1 blinker flash a...

Page 12: ...setting permits to remove the acoustical signal when the system is armed disarmed By default the Beeps are enabled F 8 OFF Disable CAN BUS command to drive the HORN When the selection used for the veh...

Page 13: ...us to pulsed Use this setting when it s necessary to switch the WHITE wire output to pulsed mode By default the output is continuous F 23 ON Inhibit the Alarm for Jammer frequency This setting permits...

Page 14: ...R It s possible to install the 2 4 GHz transmitters on door windows and locker Put the transmitter on the fixed part and the magnet on the mobile part door or windows as showed in the picture 0 0 7cm...

Page 15: ...ponder or transmitted by levering with a flat screwdriver Remove the battery from the house Replace it with a new battery type CR2032 or equivalent Do not open the batteries The liquid that can escape...

Page 16: ...kforce to replace and repair the above mentioned parts the supply of materials that have become necessary after the above mentioned actions and pertinent to them Are payable by the buyer the replaceme...