Page
11
of 16 HPS 848 R.2
Installer Section
SET-UP PROGRAMMABLE FUNTION
It’s possible to modify the function
s written in this table, the functions are valid for
LIST 35
.
To set/unset them, alarm has to be disarmed and driver door opened, press the programming
button many times as the number of the function to set/unset.
The function will be set if it was
unset and will be unset if it was set.
1 beep, 1 blinker flash and 1 LED flash.
The function is set.
2 beeps, 2 blinker flashes and 2 LED flashes.
The function is unset.
N° Function and
initial state
FUNCIONS
DESCRIPTION
F. 2
OFF
LEARNING WIRELESS SIREN
The Patrolline wireless sirens must be learned by the alarm in order to work.
Both siren and alarm must be in the learning condition.
Alarm side:
enter in the programming procedure (2 button presses), the LED flashes
quickly. Within 30 seconds set the siren in the learning procedure.
Siren side:
enter in the programming procedure grounding 10 times the BROWN siren
wire (hood input), the siren emits a series of beeps until it is detected by the alarm
(beeps became more frequent).
The learning procedure can end too by grounding again the hood input, so
it’s better to
disconnect the hood wire (if used) to enter in the procedure.
Warning:
once the alarm has been learned, every time that the system is armed, alarm
checks the presence of the siren expecting a transmission receiving, so if you need to
remove the siren, you have to erase the siren or disable the "beacon" communication by
setting the function 29.
Erasing the siren.
Enter in the learning procedure, when the LED starts flashing quickly,
press again for 5 seconds the pushbutton until 1 blinker flash and 1 beep. Siren is erased.
F. 3
OFF
HPA975 Magnetic sensors learning in the ZONE n°1
Area 1 is not temporary disabling by the remote control.
-
Push the programming button for 3 times, the LED flashes quickly;
-
During the LED flashing turn ON the magnetic sensor to learn it;
-
The correct learning is indicated by a beep, a flash lamp and the 1 sec. LED ON.
Repeat the procedure for each magnetic sensor to learn.
The procedure can stop after 30 seconds from the last learned device or after turned ON
the ignition key. The maximum number of the devices accepted into the
area 1 is 24.
Erasing all zone1 sensors.
Enter in the learning procedure, when the LED starts flashing
quickly, press for 5 seconds the button until a beep, a flash lamp and the 1 sec. LED ON.
F. 4
OFF
HPA975 Magnetic sensors learning in the ZONE n°2
Area 2 is temporary disabling by the remote control.
-
Push the programming button for 4 times, the LED flashes quickly;
-
During the LED flashing turn ON the magnetic sensor to learn it;
-
The correct learning is indicated by a beep, a flash lamp and the 1 sec. LED ON.
Repeat the procedure for each magnetic sensor to learn.
The procedure can stop after 30 seconds from the last learned device or after ignition ON.
The maximum number of the devices accepted into the
area 2 is 8.
Erasing all zone2 sensors.
Enter in the learning procedure, when the LED starts flashing
quickly, press for 5 seconds the button until a beep, a flash lamp and the 1 sec. LED ON.