Installer Section 

F. 5 
OFF 

HPA974 remote controls and HPA977 Transponder learning

 

 

To learn the additional remote controls and Transponders, the selectors on the central 
unit must be positioned as showed on the vehicle compatible list, for CAN BUS vehicles, 
or on the selection 0-1, for no CAN BUS vehicle. Learning procedure: 

1.

 

Push the programming button for 5 times, the LED flashes quickly; 

2.

 

To learn a remote control, push a button of the three on it; 

3.

 

To  learn  a  transponder,  open  its  case,  remove  and  insert  again  the  battery,  the 

transmitter sends its code for 10 seconds to permit the learning; 

The correct learning is indicated by 1 beep, 1 flash of the lamps and 1 sec. LED ON. 
Repeat  the  operation  from  point  2  with  other  remotes  or  transponders  in  case  of 
multiple devices to learn. 
The procedure can stop after 30 seconds from the last learned device, after the learning 
of the maximum remote controls and transponder accepted or after ignition ON. 
The maximum number of the remote controls accepted is 4. 

Erasing all transmitters.

 Enter in the learning procedure, when the LED starts flashing 

quickly, press  for 5  seconds the  button until a beep, a flash  lamp and the 1 sec. LED 

ON. 

F.6 

Pulsed

 

Set the alarm output (White/Red wire) from pulsing to continuous 

Program 

this setting when it’s used a siren instead of the 

horn of the car. 

Default the output is pulsed during an alarm cycle. 
To obtain a continuous siren output, program this function. 
Attention: in case of some vehicles, where the Horn is controller through the CAN BUS, 
this setting is ignored, to stop using horn by CAN BUS use function F.8. 

F.7 

OFF 

Remove the arm/disarm/warning beeps, Off/On (White/Red wire) 

This  setting  permits  to  remove  the  acoustical  signal  when  the  system  is 
armed/disarmed.  
By default, the Beeps are enabled. 

F.8 

OFF 

Disable CAN BUS command to drive the HORN 

When the selection used for the vehicle is set to command the horn by the CAN BUS, 
this setting disable this command. 
Hardware commands (White/Red or White wire) are, however, always enabled. 

F.9 

OFF 

Force Blinkers output for external Relay command 

When  the  selection  used  for  the  vehicle  command  the  blinker  by  the  CAN  BUS  or  by 
hazard  wire  through  YELLOW/GREEN  wire,  this  setting  permits  to  switch  the  mode  of 
working  of  the  YELLOW  /GREEN  wire  to  command  an  external  relay  to  drive  the 
indicator lights lamps directly.

 

F.10 

OFF 

ANTI-AGGRESSION  

For operation see the user section 

SPECIAL PROTECTION FUNCTION

” on 

page 5. 

NOTE: The engine stop is not automatic, it must also be set by 20 function. 

F.11 

OFF 

ANTI-THEFT FUNCTION 

For operation see the user section 

SPECIAL PROTECTION FUNCTION

” on 

page 5. 

NOTE: The engine stop is not automatic, it must also be set by 20 function.

 

F.12 

1 s. 

Set 30 seconds / 1 second CDL locking  

This  setting  permits  to  extend  the  locking  time  till  to  30  seconds,  to  enable  the 

COMFORT  function  where  it’s possible

,  by the HPA 974.  In  case  of Ultrasonic/Comfort 

exclusion,  by  second  locking  command  press,  the  time  will  be  reset  and  the  windows 
closing will stop. 

F.13 

Single 

Lock impulse double/single  

This setting permits to have two locking pulse instead than one, during the locking by 
the HPA 974. 

F.14 

Single

 

Unlock impulse double/single 

This setting permits to have two unlocking pulse instead than one, during the unlocking 
by the HPA 974.

 

F.15 

OFF 

Blinkers flashes at arming/disarming by the HPA 974 ON/OFF 

This  setting  permits  to  obtain  to  flash  the  blinkers  when  lock  and  unlock  the  vehicle 
with the HPA 974. 

ATTENTION: 

do  this  setting  only  if  the  lock  by  the  HPA  974  doesn’t  give  any  original 

blinkers flashes.

 

Summary of Contents for HPS 848R

Page 1: ...n unit Each update adds new vehicles while maintaining compatibility with earlier In the box there is a summary of those codes but you may want to download from the site www patrolline it the updated...

Page 2: ...both in synchronous with the original ones or independently for greater safety see programmable functions n 5 and n 26 HPS 977 With the addition of a transponder is possible to manage transparently th...

Page 3: ...it turn on the key PRESSING THE TRUNK RELEASE OF ORIGINAL REMOTE CONTROL If the device is armed the triggers for trunk opening shock and ultrasonic sensor will be inhibited to permit the access the t...

Page 4: ...opening of the door until turn on the key BUTTON 1 2 Exclusion zone 2 sensors Simultaneously pressing buttons 1 and 2 after 10 sec of the insertion system for excluding the alarm signal of the program...

Page 5: ...10km h speed threshold and if the system cannot detect the recognition after 40 seconds the alarm system actives the siren sound for 20 seconds pre alarm form now if the vehicle speed falls below the...

Page 6: ...when the trunk will physical open the ultrasonic sensor and shock sensor will be disarmed to avoid the alarm trigger These protections will be armed again when the trunk will physical close These func...

Page 7: ...when the alarm is armed via the ignition key as per the procedure detailed below 1 Turn the ignition key ON OFF as many times as per the first digit e g 1 in case of factory setting The LED is illumi...

Page 8: ...dashboard will flash twice To remind that the Valet function is active the LED on the dashboard will flash twice at any time one turns on the ignition key Deactivation Compose using the ignition key...

Page 9: ...ive WHITE GREEN 13 Negative output for confort 100mA GREEN 14 BLUE 4 BROWN 7 BROWN 7 out negative module 100mA ORANGE 8 2 out positive fixe PINK 3 Negative input for ultrasonic free 1 2 3 4 Negative o...

Page 10: ...pened F 5A Battery Negative Battery positive Description The HPS 98 siren operating with 2 4 GHz wireless technology Once learned to an alarm unit it will become like a normal wired siren adding addit...

Page 11: ...beacon communication by setting the function 29 Erasing the siren Enter in the learning procedure when the LED starts flashing quickly press again for 5 seconds the pushbutton until 1 blinker flash a...

Page 12: ...setting permits to remove the acoustical signal when the system is armed disarmed By default the Beeps are enabled F 8 OFF Disable CAN BUS command to drive the HORN When the selection used for the veh...

Page 13: ...us to pulsed Use this setting when it s necessary to switch the WHITE wire output to pulsed mode By default the output is continuous F 23 ON Inhibit the Alarm for Jammer frequency This setting permits...

Page 14: ...R It s possible to install the 2 4 GHz transmitters on door windows and locker Put the transmitter on the fixed part and the magnet on the mobile part door or windows as showed in the picture 0 0 7cm...

Page 15: ...ponder or transmitted by levering with a flat screwdriver Remove the battery from the house Replace it with a new battery type CR2032 or equivalent Do not open the batteries The liquid that can escape...

Page 16: ...kforce to replace and repair the above mentioned parts the supply of materials that have become necessary after the above mentioned actions and pertinent to them Are payable by the buyer the replaceme...

Reviews: