Troubleshooting
These troubleshooting guidelines are not intended to be all-inclusive or to substitute
the expert diagnosis of your local Intermountain certified water professional.
Hard (untreated) water to service
Cause
Solution
Open or defective bypass
Close or verify bypass
Loss of resin
Refer to problem “Loss of resin”
System fails to regenerate
Refer
to problem “System fails to clean”
Valve fails to draw brine
Refer to problem “Valve fails to draw brine”
Decreasing exchange capacity of resin Clean, augment, or replace resin bed
No salt in brine tank
Add salt
Leak at riser tube
Verify that riser tube is seated correctly and is not damaged by
heat or high water pressure
Pur-Gard supply exhausted
Refill Pur-Gard feeder
System fails to clean
Cause
Solution
Faulty electrical supply
Verify electrical service
–
Confirm unswitched power outlet
Obstructed flow meter
Clean and/or replace flow meter
Damaged PCB
Replace PCB
Damaged drain motor
Replace drain motor
Summary of Contents for Pro SXTi
Page 1: ...Patriot Pro SXTi Service Manual Revised 2019...