background image

Your  system  is  designed  to  address  certain  impurities  in  your  water  through  the 

processes  of  ion  exchange  and  physical  filtration.  Your  system  should  only  be 

installed on water that is microbiologically safe. For optimum performance, and to 

ensure  complete  warranty  protection  the  Patriot Pro  SXTI  System  should  only 

be installed when the following criteria are met: 

Minimum 

Maximum 

Water Temperature 

40 F 

75 F 

Water Pressure 

30psi 

80psi 

Influent Water Hardness 

0gpg 

100gpg 

Influent pH 

6.7 

8.7 

Influent TDS 

10 ppm 

1000 ppm 

Pathogenic Bacteria 

0 CFU 

0 CFU 

Chlorine 

0 ppm 

1 ppm 

Chloramine 

0 ppm 

1 ppm 

Ambient Temperature 

40 F 

90 F 

Evertech controller 

Your  Patriot Pro  SXTI  System  is  smart  as  a  result  of  the  exclusive  Evertech  control  platform. 
This advanced  microprocessor  control  system  incorporates  the  latest  hardware  and  software  to 
ensure that  your  water  is  the  very  best  that  it  can  be.  Your  system  can  also  be  upgraded  with 
the  latest software and hardware as they become available. See your authorized dealer for more 
information. 

During Service 

The control center constantly monitors water usage in your home, learning your lifestyle and adapting 
itself to ensure that you have a consistent supply of softened water. 

The control center makes daily decisions about how  and when it should clean itself using the  latest 
algorithms  that  consider  your  water  usage  habits,  water  hardness,  and  other  programmed 
parameters. 

Your system will periodically  perform an antibacterial  deep cleaning. This cleaning cycle  will  occur 
after a designated period of time (we recommend at least every once a week). This cleaning cycle will 
inject Pur-Gard into your system and possibly even use salt to clean itself, depending on your 

water 

usage. If you haven’t used any water during that interval, the system will not use any salt during 

the antibacterial cleaning cycle. 

During a Cleaning Cycle 

Once your system determines that it needs to be cleaned, it will initiate a cleaning cycle. The cleaning 
cycle is controlled by the Evertech control center and cycle times will vary depending on  your water 
usage habits, the system operational  history, and other programmed parameters.  You should try to 
avoid using softened water during this time, particularly after the percolation cycle. 

Summary of Contents for Pro SXTi

Page 1: ...Patriot Pro SXTi Service Manual Revised 2019...

Page 2: ...get to study the long term health effects of the more than 70 000 harmful chemicals that can be found in use today Approximately 1 000 new synthetic chemical compounds are entering the industrial mark...

Page 3: ...loors Hardness and other dissolved solids combine to form the residue you see as spots on glasses crockery cutlery and shower enclosures Hard water harms fabrics Laundry washed in hard water takes on...

Page 4: ...rms an insulating layer that prevents the burners or heating elements from heating the water efficiently Just 1 8 of scale inside the tank can require up to 30 more fuel to heat the water to the desir...

Page 5: ...maged Clothing Excessive Soap Consumption Pipe Scaling Faucet and Fixture Damage Skin Problems Unpalatable Food Undesirable Tastes and Odors Premature Appliance Failure Unsatisfactory Laundry Results...

Page 6: ...become available Reliable The mechanical subsystem in the Patriot Pro is revolutionary in its own right The Patriot Pro is built around Open platform TM technology building on a 40 year legacy of reli...

Page 7: ...sibly even compromise system functionality Consult with your local water professional to decide on the best salt for your application Pur Gard The Pur Gard injection feeder should be kept full to ensu...

Page 8: ...sumption habits always maximizing efficiency and performance while providing you with the water quality that you deserve Pur Gard is designed to Clean ion exchange resin without damaging structured ma...

Page 9: ...algae mold and fungus that can enter the system through safe city water salt or even from the air These additional contaminants slowly accumulate in your softener and can even colonize it with a biof...

Page 10: ...ystem Observe flow of water from the bathtub Water will become a dark brown black color This color is caused by the system disinfectant preservative as well as dust from shipping handling Allow water...

Page 11: ......

Page 12: ...ring regeneration Data Display During Service Mode Displays Time of Day and capacity remaining During cleaning mode Counts remaining cycle time PM Indicator Lit when time being displayed is after noon...

Page 13: ...at cycle to execute Flow meter In service mode the display will show the time of day and remaining capacity the remaining capacity counter counts backwards in gallons By opening a faucet downstream of...

Page 14: ...ogramming parameters DO Set the anti bacterial day override setting The system will cycle at least once during the time interval set here If you don t use any water the system will not use any salt RT...

Page 15: ...RATE Displays the current real time flow rate through the system PF PEAK FLOW RATE Displays the highest flow observed by the system since the last regeneration HR HOURS IN SERVICE Displays the total n...

Page 16: ...acement of the calcium and magnesium ions in the water by an equivalent number of sodium ions The Softening process may be illustrated by the following equation R2 Na Ca HCO3 2 R2 Ca 2NaHCO3 Sodium Io...

Page 17: ...mation During Service The control center constantly monitors water usage in your home learning your lifestyle and adapting itself to ensure that you have a consistent supply of softened water The cont...

Page 18: ...e water in the home during this time Backwash Your system rapidly discharges water upwards through the resin media bed and to the drain This backwash step ensures that trapped sediment and broken resi...

Page 19: ...o clean Valve fails to draw brine Refer to problem Valve fails to draw brine Decreasing exchange capacity of resin Clean augment or replace resin bed No salt in brine tank Add salt Leak at riser tube...

Page 20: ...nks restrictions or obstructions Leak in brine line Verify brine line and connections for air leakage Insufficient water in brine tank Refer to problem Valve fails to refill brine tank Excessive water...

Page 21: ...sehold for excessive or unexpected water usage leaky toilet fill valves T P Relief drainage Reverse Osmosis processors humidifiers plumbing leaks etc Salty water to service Cause Solution Excessive wa...

Page 22: ...up in resin tank Clean resin bed and control valve increase regeneration frequency Increase Pur Gard dosage rate Plugged lower and or upper distributor Verify that distributors are free of debris Cru...

Page 23: ...quired by applicable law Intermountain Soft Water shall not be liable for any damages whatsoever including without limitation loss time inconvenience expenses such as telephone calls labor or material...

Reviews: