Diagnostics Mode
Diagnostics mode is accessed as follows:
Press the
UP
and
EXTRA CYCLE
buttons together and hold them in
for at least 5 seconds Press the
UP
button to scroll through the data
Press the
RECYCLE
button to exit
diagnostics
mode
The following diagnostic data is available for viewing:
FR
FLOW RATE
Displays the current real-time flow rate through the system
PF
PEAK FLOW RATE
Displays the highest flow observed by the system since the last regeneration
HR
HOURS IN SERVICE Displays the total number of hours that the system has been in service
VU
VOLUME USED
Displays the total volume of water treated by the system
RC
RESERVE CAPACITY Displays the system’s current reserve capacity
SV
SOFTWARE VERSION
System Software/Firmware version
This can be upgraded by your local authorized service agent