PATON
StandardMIG
DC MMA/TIG/MIG/MAG
- 94 -
a) 0[OFF] ... 80% (unit increment 5%)
8) Voltage pulsation frequency = 20 Hz (default)
a) 5 ... 500 Hz (unit increment 1 Hz)
9) The pulse/pause ratio (duty ratio) is the percentage of the larger current pulse to the
period of these pulses = 50% (default)
a) 20 ... 80% (unit increment 5%)
On the right wire feeder display:
0) Main displayable parameter Rate feed = 7.0 m/min (default)
a) 2.0 ... 16.0 m/min (unit increment 0.1 m/min)
1) Torch button mode = [2T] (default)
a) [2T]
–
button mode on the 2T torch
b) [4T]
–
standard button mode on 4T torch
c) [alt.4T]
–
alternative button mode on 4T torch
2) Wire feed motor on/off = ON (default)
a) ON
–
enabled
b) OFF
–
disabled
3) Pre-purge time with safety gas = 0.1 sec (default)
a) 0.1 ... 25.0 sec (unit increment 0.1 sec)
4) Post-purge time with safety gas = 0.1 sec (default)
a) 0.1 ... 25.0 sec (unit increment 0.1 sec)
5) Wire feeder ramp up speed = 0.1 sec (default)
a) 0 [OFF] ... 5.0 sec (unit increment 0.1 sec)
6) Wire feeder decay speed = OFF (default)
a) 0 [OFF] ... 5.0 sec (unit increment 0.1 sec)
8. GENERATOR OPERATION MODE
The power supply is suitable for operation on a generator under the following conditions:
When working
with an
electrode
Set current value
for MMA and TIG
When working with a wire
diameter at MIG/MAG
Generator
minimum power
Ø
2
Max.
80А
Max.
Ø
0.6 mm
3.0 kVA
Ø3
Max.
120А
Max.
Ø
0.8 mm
4.5 kVA
Ø
4
Max.
160А
Max.
Ø
1.0 mm
6.0 kVA
Ø
5 fusible
Max.
200А
7.7 kVA
Ø
5
Max.
250А
Max.
Ø
1.2 mm
10.0 kVA
Ø
6 fusible
Max.
270А
12.0 kVA
Ø
6
Up to
350А
Max.
Ø
1.4 mm
16.0 kVA