10) The pulse/pause ratio (duty ratio) is the percentage of the larger current pulse to the
period of these pulses = 50% (default)
a) 20 ... 80% (unit increment 5%)
TIG welding mode
0) Main displayable parameter CURRENT
= 100А (default
)
a) 8 ... 160
А
(unit increment 1
А
) for StandardMIG-160
b) 10 ... 200
А
(unit increment 1
А
) for StandardMIG-200
c) 12 ... 250
А
(unit increment 1
А
) for StandardMIG-250
d) 12 ... 270
А
(unit increment 1
А
) for StandardMIG-270
e) 14 ... 350
А
(unit increment 1
А
) for StandardMIG-350
1) Current ramp up time = OFF (default)
a) 0[OFF]...15.0 sec (unit increment 0.1 sec)
2) Current pulsation power = OFF (default)
a) 0[OFF] ... 80% (unit increment 5%)
3) Current pulsation frequency = 10.0 Hz (default)
a) 0.2 ... 500.0 Hz (dynamic unit increment 0.1 Hz …
1 Hz)
4) The pulse/pause ratio (duty ratio) is the percentage of the larger current pulse to the
period of these pulses = 50% (default)
a) 20 ... 80% (unit increment 5%)
MIG/MAG welding mode
On the left source display:
0) Main displayable parameter VOLTAGE = 19.0 V (default)
a) 12.0 ... 24,0V (unit increment 0,1V) for StandardMIG-160
b) 12.0 ... 26,0V (unit increment 0,1V) for StandardMIG-200
c) 12.0 ... 28,0V (unit increment 0,1V) for StandardMIG-250
d) 12.0 ... 29,0V (unit increment 0,1V) for StandardMIG-270
e) 12.0 ... 30,0V (unit increment 0,1V) for StandardMIG-350
1) Torch button mode = [2T] (default)
a) [2T]
–
button mode on the 2T torch
b) [4T]
–
standard button mode on 4T torch
c) [alt.4T]
–
alternative button mode on 4T torch
2) Inductance = OFF (default)
a) 0 [OFF] ... 3 steps (unit increment 1 step)
3) Pre-purge time with safety gas = 0.1 sec (default)
a) 0.1 ... 25.0 sec (unit increment 0.1 sec)
4) Post-purge time with safety gas = 0.1 sec (default)
a) 0.1 ... 25.0 sec (unit increment 0.1 sec)
5) Voltage ramp up time = OFF (default)
a) 0 [OFF] ... 5.0 sec (unit increment 0.1 sec)
6) Voltage decay time = 0.1 sec (default)
a) 0.1 ... 5.0 sec (unit increment 0.1 sec)
7) Voltage pulsation power = OFF (default)