2)
in the TIG mode
–
welding current;
3)
in the MIG/MAG mode
–
welding voltage.
During the MIG/MAG welding, the left display shows the current value of the current resulting from the following factors: used wire diameter, set
voltage value at the source, set wire feed speed on the feeder, gas used, material and the thickness of the workpiece to be welded, etc. The value is
shown within 8 seconds after the end of welding, this is necessary for the welder to be able to double-check the current value, without any outside help.
In the MIG/MAG mode, the digital indicator on the right side shows the value of the wire feed speed in "m/min".
Button
3
on the front panel of the unit is responsible for selecting the source function in the current welding mode, and button
10
is
responsible for selecting the function of the feeder in MIG/MAG mode.
Button
4
on the front panel of the unit is responsible for selecting the welding mode.
Buttons
1
on the front panel of the source are responsible for changing the current value on the digital indicator on the left.
Buttons
7
on the front panel of the feeder are responsible for changing the current value on the digital indicator on the right.
SWITCHING TO THE REQUIRED FUNCTION
If the unit has a system of protection against unauthorized access to the function menu, then if you press button
3
or
10
no changes are made
on the corresponding indicator, i.e., this button is locked. To unlock, hold it down for more than 3.5 seconds. When unlocked, the indicator
will display horizontal lines that begin to disappear, indicating that the function menu is being unlocked. After the lines disappear
completely, the menu will be unlocked and the button can be released. If you release the button before the lines disappear completely, the
menu unlock process will be interrupted and the menu will remain locked. After successful unlocking, pressing button
3
or
10
the
corresponding digital display shows the current function name and its value.
Caution!
After releasing button
3
after 2 seconds, the screen will return to the main parameter of the current welding mode. While the
display is showing the current function, its value can be changed up or down using buttons
1
. Alternatively, by quickly pressing and releasing
button
3
, you can switch to the next function, in a circle.
Caution!
If you hold down button
3
for more than 10 seconds, then the countdown will appear on the display 333... 222... 111 ...; release the
button before this time expires, so as not to reset all the settings of this mode to the standard factory settings.
Similarly, by pressing button
10
, the digital indicator on the right displays the graphic name of the current function of the wire feeder, and immediately
after releasing it, the current value of this function is displayed for 2 seconds. You can change the value up or down with buttons
7
.
SWITCHING TO THE REQUIRED WELDING MODE
Pressing button
4
leads to switching to the next welding mode in a circle, this can be seen on the indicators
5
on the front panel.
RESET ALL FUNCTIONS OF THE WELDING MODE USED
Situations may occur when the unit's settings have somewhat confused the user. In order to reset their values to the factory default, use the
same button
3
, used to enter the function menu. To reset the settings, simply hold down button
3
for more than 10 seconds (ignore the
animation of locks). The scoreboard will start counting down 333...222...111 and when "000" is reached, all settings of the current welding
mode will be updated to factory settings. Resetting parameters for each welding mode is performed separately! This is provided for
convenience, so as not to accidentally reset individual settings in the other two modes.
Similarly, you can reset the parameters on the wire feeder using button
10
.
GENERAL LIST AND SEQUENCE OF FUNCTIONS
MMA welding mode
0) Main displayable parameter CURRENT= 90А (default)
a) 8 ... 150А (unit increment 1А)
1) [H.St] Hot Start power = 40% (default)
a) 0[OFF] ... 100% (unit increment 5%)
2) [t.HS] Hot Start time = 0.3 sec (default)
a) 0.1 ... 1.0 sec (unit increment 0.1 sec)
3) [Ar.F] Arc Force power = 40% (default)
a) 0[OFF] ... 100% (unit increment 5%)
4) [u.AF] Arc Force triggering level = 12V (default)
a) 9 ... 18V (unit increment 1V)
5) [BAH] Voltage response slope = 1.4V/A (default)
a) 0.2 ... 1.8V/A (unit increment 0.4V/A)
6) [Sh.A] Short arc welding = OFF (default)
a) ON
–
enabled
b) OFF
–
disabled
7) [BSn] Voltage reduction unit = OFF (default)
a) ON
–
enabled
PATON
EuroMIG
DC MMA/TIG/MIG/MAG
-6 -
Summary of Contents for EuroMIG
Page 1: ......