b)
OFF
–
disabled
8)
[Po.P] current pulsation mode = OFF (by default)
a)
ON
–
enabled
b)
OFF
–
disabled
9)
[I.iP] pulse current = 90A (by default)
a)
8 ... 150A (change step 1A)
10)
[I.PS] pause current = 90A (by default)
a)
8 ... 150A (change step 1A)
11)
[Fr.P] current pulsation frequency = 5.0 Hz (by default)
a)
0.2 ... 500 Hz (dynamic change step 0.1 Hz...1 Hz)
12)
[dut] pulse/pause ratio (duty cycle) - it is the percentage of the current pulse to the period of repetition of these pulses = 50% (by default)
a)
20 ... 80% (change step 5%)
TIG welding mode
0)
Main displayable parameter CURRENT = 100А (default)
a)
8 ... 150А (unit increment 1А)
1)
[t.P0] shielding gas post-purge time = 1.5 sec (by default)
a)
0.1 ... 25.0 sec (change step 0.1 sec)
2)
[t.uP] current ramp up time = 0.3 sec (default)
a)
0[OFF]...15.0 sec (unit increment 0.1 sec)
3)
[Po.P] current pulsation mode = OFF (by default)
a)
ON
–
enabled
b)
OFF
–
disabled
4)
[I.iP] pulse current = 100A (by default)
a)
8 ... 150A (change step 1A)
5)
[I.PS] pause current = 100A (by default)
a)
8 ... 150A (change step 1A)
6)
[Fr.P] current pulsation frequency = 10.0 Hz (by default)
a)
0.2 ... 500 Hz (dynamic change step 0.1 Hz...1 Hz)
7)
[dut] pulse/pause ratio (duty cycle)
–
it is the percentage of the current pulse to the period of repetition of these pulses = 50% (by default)
a)
20 ... 80% (change step 5%)
MIG/MAG welding mode
On the left source display:
0)
Main displayable parameter VOLTAGE = 19.0 V (default)
a)
12.0 ... 23,0V (unit increment 0,1V)
1)
[Ind] Inductance = OFF (default)
a)
0 [OFF] ... 6 steps (unit increment 1 step)
2)
[t.Pr] shielding gas pre-purge time = 0.1 sec (default)
a)
0.1 ... 25.0 sec (unit increment 0.1 sec)
3)
[t.P0] shielding gas post-purge time = 0.1 sec (default)
a)
0.1 ... 25.0 sec (unit increment 0.1 sec)
4)
[t.up] Voltage ramp up time = OFF (default)
a)
0 [OFF] ... 5.0 sec (unit increment 0.1 sec)
5)
[t.dn] Voltage decay time = 0.1 sec (default)
a)
0.1 ... 5.0 sec (unit increment 0.1 sec)
6)
[Po.P] voltage pulsation mode = OFF (by default)
a)
ON
–
enabled
b)
OFF
–
disabled
7)
[u.iP] pulse voltage = 19V (by default)
a)
12 ... 23.0V (change step 0.1V)
8)
[u.PS] pause voltage = 19V (by default)
a)
12 ... 23.0V (change step 0.1V)
9)
[Fr.P] voltage pulsation frequency = 20Hz (by default)
a)
5 ... 500 Hz (step change 1 Hz)
10)
[dut] pulse rate (duty cycle)
–
it is the percentage of the voltage pulse to the period of repetition of these pulses = 7% (by default)
a)
2 ... 20% (change step 1%)
On the right wire feeder display:
0)
Main displayable parameter Rate feed = 7.0 m/min (default)
a)
1.5 ... 10.0 m/min (unit increment 0.1 m/min)
-
when wire feeder menu is locked (by pressing button
11
):
1) [But] torch button mode = 2T (default)
a)
[2T]
–
button mode on the 2T torch
b)
[SPOT]
–
SPOT mode
-7 -
PATON
EuroMIG
DC MMA/TIG/MIG/MAG
Summary of Contents for EuroMIG
Page 1: ......