b)

 

[4T] 

 standard button mode on 4T torch 

 

2)

 

[t.SP] point time = 2 sec (default) - when SPOT mode is activated (by holding button 

11

 for 1-2 seconds) 

a)

 

0.2 ... 10.0 sec (unit increment 0.1 sec) 

 

-

 

when wire feeder menu is unlocked (by pressing button 

11

): 

3) [Dru] wire feed motor on/off = ON (default)

 

 

a)

 

ON 

 enabled 

b)

 

OFF 

 disabled 

4)

 

[t.Pr] pre-purge time with safety gas = 0.1 sec (default) 

a)

 

0.1 ... 25.0 sec (unit increment 0.1 sec) 

 

5)

 

[t.P0] post-purge time with safety gas = 0.1 sec (default) 

a)

 

0.1 ... 25.0 sec (unit increment 0.1 sec) 

6)

 

[t.uP] wire feeder ramp up speed = 0.1 sec (default) 

a)

 

0 [OFF] ... 5.0 sec (unit increment 0.1 sec) 

7)

 

[t.dn] wire feeder decay speed = OFF (default) 

a)

 

0 [OFF] ... 5.0 sec (unit increment 0.1 sec) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

PATON 

EuroMIG

 DC MMA/TIG/MIG/MAG

 

-8 -

 

Summary of Contents for EuroMIG

Page 1: ......

Page 2: ...orn goggles must be equipped with goggles with a DIN 9 10 filter Unauthorized persons in the operating area of the device must protect their eyes with special goggles or use non flammable radiation ab...

Page 3: ...pneumatic connector 1 Buttons to adjust the selected parameter to decrease and increase default for MMA welding current for TIG welding current MIG MAG welding voltage 2 Digital display 3 Button for s...

Page 4: ...der shall be connected START UP The welding unit is designed exclusively for MMA welding tungsten arc inert gas TIG welding as well as metal arc inert gas welding metal active gas welding MIG MAG Othe...

Page 5: ...ains after completion of welding Machine connection diagram for welding with stick electrodes MMA electrode holder ground terminal piece Recommended length of power welding cables during welding Maxim...

Page 6: ...ht of the coil kg 5 MMA 0 2 500 Pulsed welding modes TIG 0 2 500 MIG MAG 5 500 Stick electrode diameter mm 1 6 4 0 Hot Start in MMA mode Adjustable Arc Force in MMA mode Adjustable Anti Stick in MMA m...

Page 7: ...e the display is showing the current function its value can be changed up or down using buttons 1 Alternatively by quickly pressing and releasing button 3 you can switch to the next function in a circ...

Page 8: ...on of these pulses 50 by default a 20 80 change step 5 MIG MAG welding mode On the left source display 0 Main displayable parameter VOLTAGE 19 0 V default a 12 0 23 0V unit increment 0 1V 1 Ind Induct...

Page 9: ...d motor on off ON default a ON enabled b OFF disabled 4 t Pr pre purge time with safety gas 0 1 sec default a 0 1 25 0 sec unit increment 0 1 sec 5 t P0 post purge time with safety gas 0 1 sec default...

Page 10: ...nnectors with traces of corrosion which caused a malfunction out of order due to exposure to its power and electronic elements of abundant moisture failed due to the accumulation of conductive dust in...

Page 11: ...__________________________________________________________________________________ ___________________________________________________________________________________________________________________ _...

Page 12: ...________________________________________________ ___ Date of receipt for repair _________________ _____ 20____ _____________________________ signature Symptoms of non operability _____________________...

Reviews: