19
3
3.3.3.
<Set ID for this product>
Sending data in the following form will change the ID of this product. Two ASCII bytes are designated in the data
section to change to a new ID. The configuration range for each byte of data in the data section can set up from 0
[30H] to ? [3FH].
[Transmission Example]
In this example, the ID set at 56 [35H 36H] shall be changed to 21 [32H 31H].
• Send Data
Header
ID
Command
Data
End Code
@
[40H]
5
[35H]
6
[36H]
?
[3FH]
2
[32H]
1
[31H]
!
[21H]
• Reply data
Normal response
Data
ACK
[06H]
Response Error
Data
NAK
[15H]
The following are conditions which will get a NAK reply and the error contents.
Transmission Condition
Error Contents
Command error
When a command other than on the list of commands is specified
Data error
When data, other than 0[30H] - ?[3FH], is used
Data size error
When the number of bytes in the send data is different
Timeout
Reply interval between data is more than 5 seconds after receipt of header
* Do not transmit the following command, before this product transmits reply data. It may not operate
normally.