2.8. Wiring Example
The internal contacts are non-voltage relay contacts. Operate the Terminal Buss below a contact capacity of
DC30V at 3A. In addition, since each contact is independent, different voltages can be connected to the product
for each contact. The Power Supply Output Terminal can supply a maximum current of 500mA at DC24 Volts.
2.8.2.1.
<DC Load Products>
2.8.2.2.
<AC Load Products>
MEMO
• Use the AC Adaptor when using the Power Supply Output Terminal in the wiring example.
<PHC-D08>
Power Supply Wire (Positive)
Power Supply Wire (Negative)
Signal Light, Signal Tower,
Alarm/ Voice Synthesizer
Power Supply
Output Terminal
USB or RS-232C
Cable
+
-
Control Device
(PC)
AC Adaptor
<PHC-D08>
AC Load Products
Power Supply
Output Terminal
USB or RS-232C Cable
+
-
Control Device
(PC)
AC Adaptor
Relay
AC Power Supply