background image

 

 
 
 
 
 
 

 

FOR OUTDOOR USE ONLY 

 

USE FOR PROPANE/BUTANE ONLY 

 

MAX. WATTAGE  13000W 

 

MIM. WATTAGE    5000W 

 

HEAT CAPACITY  43,000BTU/h 

 

CONSUMPTION 

450g/h-870g/h 

 

WEIGHT 

 

22KG 

 

HEIGHT 

 

2250mm 

 
 

This appliance has been subjected to an AGA test and has been 

registered with the corresponding CE labelling. 

 
 

Country of Manufacture 

Taiwan 

 
 

Table of orifices 

 

Gas pressure 

mm H

2

Main orifice 

diameter in mm 

Orifice pilot burner 

in mm 

280/300 

1.8 

0.25 

 
 
 
 

 

 

 

 

0085 

 

 
14 

 
 
 
 

 

This outdoor gas appliance is for outdoor use only and must not 
be used in a building, garage or any enclosed area. 

 

The pressure regulator and hose assembly supplied with the patio 
heater must be used.  Replacement regulator and hose assembly 
must be those specified by the manufacturer. 

 

Patio Heater must be placed on a solid and level surface. 

 

Always ensure ample fresh air for ventilation. 

 

Maintain proper clearance to combustion chamber (top 50cm sides 
60cm). 

 

Do not attempt to alter the unit in any manner. 

 

Prior to each use check the patio heater for any wear to the hose, 
regulator, pilot and burner. 

 

Do not transport heater while it’s operating.  Allow to cool down 
before moving. 

 

All leak tests should be done with a soapy solution

.

 

 

NEVER USE AN OPEN FLAME TO CHECK FOR LEAKS. 

 

Check the heater immediately if any of the following exists: 

o

 

The heater does not reach temperature 

o

 

The burner makes a popping noise during use (a slight noise is 

normal when the

 

burner is extinguished

).

 

o

 

The smell of gas in conjunction with

 

extreme

 

yellow tipping on 

the burner flame. 

Maintenance Instructions: 

o

 

Do not clean heater with cleaners that are combustible or 
corrosive 

o

 

Check and clean burner tubes for insect debris. 

o

 

Do not paint radiant screen, control panel or canopy reflector 

 

GAS REQUIREMENTS 

 

 

Use propane only.  The regulator and high pressure hose are 
supplied for propane use only.  To convert to butane please 
consult with a qualified gas engineer. 

 

Never connect to an unregulated propane tank. 

 

A dented, rusted or damaged propane tank may be hazardous and 
should be checked by your gas supplier.  Never use a propane 
tank with a damaged valve connection. 

 

 

 

 

TECHNICAL DATA & SPECIFICATIONS

 

 

 

PLEASE READ THE SAFETY GUIDELINES  

PRIOR TO OPERATION OF THE HEATER

 

 

Summary of Contents for BFX740

Page 1: ...ban Industry Limited All rights reserved www patioheaters4u com Printed in the UK Model No BFX740 Terrace Patio Heater Operating Instructions Safety Information 2 Assembly Parts 4 Setting Up 6 Heater...

Page 2: ...ound defective at the purchaser s risk and expense 3 This guarantee shall not apply to damage caused through fire accident lightening misuse neglect incorrect adjustment or repair transit damage wear...

Page 3: ...to the hose regulator pilot and burner Do not transport heater while it s operating Allow to cool down before moving All leak tests should be done with a soapy solution NEVER USE AN OPEN FLAME TO CHEC...

Page 4: ...t 4 PROBLEM PROBABLE CAUSE SOLUTION Pilot will not light Gas valve may be OFF Turn gas valve ON Tank fuel empty Refill LPG tank Opening blocked Clean or replace Air in supply system Purge air from lin...

Page 5: ...mum temperature TO TURN OFF THE HEATER 1 Press the pilot light button 2 Shut off the valve from the gas supply cylinder completely Igniter button Max heat button Min gas flow control Max gas flow cont...

Page 6: ...the gas supply and call your gas supplier The heater must be checked with a full cylinder Do not use the heater until all connections have passed a leak test Only use parts recommended Substitute part...