Programming
© 1996-2001 by PAT GmbH
∙
D-76275 Ettlingen
∙
Hertzstr. 32 - 34
∙
++49 (0) 7243 709-0
∙
FAX ++49 (0) 7243 709-141
20
19_1272E.DOC / 2001-04-02 / Rev. C / ko.
·
Invalid operating modes are displayed by means of "EEEE".
The system is now ready for operation. The cutoff of the crane movements is canceled and pilot
lamps and audible alarms are turned off.
The
data display
(1) now shows the present data.
WARNING
Failure to properly program the LMI with the correct operating code may result in property
damage or serious bodily injury or death to personnel.
To assure the crane is properly programmed, verify that the operating code and the load
capacity chart match the lifting configuration of the crane.
4.2
Adjustment of the Reeving
The button
"Reeving"
(7) serves for the input of the present reeving of hook block. The number of
reeving is entered on the
numerical keypad
(14) by selecting the respective number. The reeving is
displayed on the
data display
(1) (see also #L; chapter 3.4).
The reeving is adjusted as follows:
a) Start the adjustment procedure by pressing the button "
Reeving"
(7).The key lights up.
b) Enter the reeving in the
numerical keypad
(14)
Now, the entered reeving is shown on the reeving display.
c) Acknowledge the input by pressing key
„C“
(15)
Upon actuation of key „C“ (15) the entered reeving is acknowledged, i.e. the input is only valid after the
acknowledgment. The button Reeving (7) is normally lit again.
WARNING
The correct setting is of utmost importance for the proper function of the system and the
crane.