Troubleshooting
© PAT Rev. 8 05/19/03
191319_8.DOC
39
9.3 OPERATING
ERRORS
Malfunctions in the system which are caused by range exceeding or operating errors by the crane
operator himself are indicated on the display together with an explanation. These error codes are E01,
E02, E03, E04, E05, E18 and E83 and they can normally be eliminated by the crane operator himself.
ERROR
CODE
CAUSE
ELIMINATION
E01
Fallen below the minimum radius
or above the angle given in the
load capacity chart due to luffing
up the boom too far.
Boom down to a radius or angle given
in the load capacity chart.
E02
The maximum radius or minimum
angle given in the load capacity
chart was exceeded due to luffing
down the boom too far.
Boom up to a radius or angle given in
the load capacity chart.
E03
Boom position is out of the
permissible working area
(over front).
Move boom back to the permissible
working area.
See lifting diagram in the load capacity
charts.
E04
Operating mode switch in the
console incorrectly set.
Correctly set operating mode switch to
the code assigned to the operating
mode of the crane.
Operating mode is not
permissible with the actual crane
configuration, boom position or
area definition.
Be sure crane is set up according to
proper operating configurations.
E05
Boom was telescoped too far or
not far enough, you may only
operate up to a certain maximum
or minimum boom length or with
load curves for boom extension
where you have to telescope the
main boom to a certain length.
Telescope boom to correct length,
given in the load capacity chart.
Length sensor adjustment
changed i.e. length sensor cable
slid off the length sensor drum.
For elimination refer to service manual.