General Information
© PAT Rev. 8 05/19/03
191319_8.DOC
9
Audible
Alarm
The AUDIBLE ALARM (12), sounds during the following conditions:
overload
condition
approaching two-block condition
preset limits reached
malfunction of the LMI system
operating
error
The alarm can be temporarily silenced by pushing the button “Alarm
Stop” (6).
Key
Switch
The
anti-two-block
switch cut-off function is deactivated
when the KEY SWITCH (13) is turned to position "B"
and
the “By-
pass A2B” button (14) is pushed.
or
The
LMI
cut-off function is deactivated when the KEY
SWITCH (13) is turned to position "B"
and
the “By-pass LMI” button
(15) is pushed.
KEY SWITCH (13) can be operated only by using the matching key.
Since button (14) and (15) deactivate the cut-off function of the LMI system / the anti two-block
system, the following instructions must be obeyed:
•
The by-pass function shall be used with discretion, as unwarranted use of it to override the
control lever lockout system can result in harm to the crane and danger to property and
persons.
•
Never use the by-pass function to either overload or operate the crane in a non-permissible
range.
Summary of Contents for DS 350 / 1319 Graphic
Page 3: ......
Page 5: ......
Page 11: ...Operator s Manual DS 350 1319 PAT Rev 8 05 19 03 191319_8 DOC 6 Fig 2 Operating Console...