Configuration Setup
© PAT Rev. 8 05/19/03
191319_8.DOC
15
4.2
QUICK SETTING OF THE REEVING
If, during the crane operation, the number of reeving is modified, the LMI system has to be adjusted to
this modification. The input of the reeving can be carried out directly without having to go through the
whole LMI programming procedure again:
Call LMI Programming
Procedure.
Directly call function "Quick
Setting of the Reevings".
Note:
The direct call is impossible, if
the system has been turned off
for more than 2 hours.
Input Of Reeving:
Increase Reeving
Decrease Reeving
Confirm Reeving
F1
F2
F3
F4
Confirm Modification.
(Select Again The Function
Upon Faulty Input)
Note:
If a configuration is selected which is not available on the present crane, the system will not accept the selection
and the display will indicate the error code E04.