37
Cantinola Touch 2016 operating and maintenance manual
Er04
The machine turns off because the
water temperature in the boiler is too
high
1) Water temperature is too
high (over 85 °C), reduce
the temperature set in the
boiler.
2) Check that no air has
formed inside the system
circuit.
3)*Check the heating system
circulator operates correctly
BOILER WATER
TEMPERATURE
PROBE
Er05
Turning off for fumes over
temperature
1) *Check
the
correct
operation and positioning
of the fumes temperature
probe.
2) *Check
the
chimney
draught is not excessive.
3)*Check the heating system
circulator operates correctly.
SMOKE
TEMPERATU
RE PROBE
Er07
Encoder error, it can take place if
the Encoder signal is missing
*Check that the encoder
connection cables are in
place
TACHOMETE
R ON
EXTRACTOR
MOTOR
Er08
Encoder error, it can take place
because of problems in adjusting
the number of revolutions
*Check that the extractor is
not blocked
TACHOMETE
R ON
EXTRACTOR
MOTOR
Er09
Water pressure is below the
minimum allowed level
*Load the boiler up to
1.2 bar
WATER
PRESSURE
TRANSDUCE
R
Er10
Water
pressure
is
over
the
minimum allowed level
*Discharge the boiler when
cold up to 1.2 bar
WATER
PRESSURE
TRANSDUCE
R
Er11
Clock error
Check the settings of the
internal clock
Er12
Turning off for failed ignition
1) Repeat the ignition phase
after emptying the brazier
tray;
2) Check
that
pellet
is
present in the tank.
3) *Check the auger is not
blocked
SMOKE
TEMPERATU
RE PROBE
Er15
Turning off for lack of power
supply lasting longer than 50
minutes
* TO BE PERFORMED BY A QUALIFIED TECHNICIAN ONLY.