Cantinola Touch 2016 operating and maintenance manual
TROUBLESHOOTING
In order to facilitate the diagnostic phase, refer to the error messages list and their description,
possible solution and probe detecting the error.
ERRORS MESSAGES
ERRORS
SHOWN
ERROR DESCRIPTION
SOLUTIONS
PROBE
OPERATING
Er01
It refers to the
Manual Reset Safety
Thermostat
has intervened (it is
located on the rear connection
panel). In any operation status,
when the temperature in the boiler
is higher than safety temperature
(about 95°C), it activates the
TURNING
OFF
status
and
subsequently the
BLOCK
status. The
intervention can take place also
when the stove is turned off.
1) Check the condition of
the
manual
reset
thermostat and re-activate
it, if necessary. To do this,
push the white button using
a pointed object. Be careful
to fully push the button to
correctly
reset
the
thermostat.
MANUAL
RESET
SAFETY
THERMOSTAT
Er02
It refers to the smoke pressure
switch which put the boiler in
SWITCH OFF
state and then to
BLOCK
, when the boiler is working.
Security can only intervene when
the boiler is not switched off.
1) To check the smoke outtake
is not obstructed and that the
chimney has a good draught, as
reported
in section “chimney”.
2) To check that the gateway
to the fireplace is closed and
it sticks well.
3) To check that the drawers for
collecting ashes are well
positioned;
4) To make sure the
ash collection drawers are
not filled up.
5) To check that
the smoke extractor works
properly.
6) The Pipe for the detection of
the air could disconnected
or broken.
7) To check the pressure switch
connection .
8) To replace the pressure
switch.
SMOKE
PRESSURE
SWITCH
Er03
The machine turns off because the
fumes temperature in the boiler is
too low
1)
To check the level of
pellet.
2)
To check the right
functioning of the
gear motor and rotary
valve for the pellet
loading
SMOKE
TEMPERATU
RE PROBE