background image

 

Parry

-British Built for Purpose 

IN173-4

 

11 

 

  Technical Information

 

 

 

Low Rates: Per Burner (All figures are NET) 

 

 

Low Rate: Total Unit (All figures are NET) 

 

 
INJECTORS 

Natural G20   = INJECT130 
Propane G31 = INJECT082 

 

 

Gas 

Operating Pressure 

Total Heat Input 

NATURAL   G20 

20mb/8”      W.G. 

1.777 KW = 6,062 Btu/h 

PROPANE  G31 

37mb/14.8” W.G. 

1,976 KW = 5779  Btu/h 

Gas Rate 

M³/HR 

FT³/HR 

LB/HR 

KG/HR 

NATURAL   G20 

0.177 

6.2467 

 

 

PROPANE  G31 

0.081 

2.855 

0.340 

0.154 

Gas 

Operating Pressure 

Total Heat Input 

NATURAL   G20 

20mb/8”      W.G. 

3.553 KW = 12,124 Btu/h 

PROPANE  G31 

37mb/14.8” W.G. 

3.952 KW = 13’485 Btu/h 

Gas Rate 

M³/HR 

FT³/HR 

LB/HR 

KG/HR 

NATURAL   G20 

0.355 

12,533 

 

 

PROPANE  G31 

0.162 

5.710 

0.681 

0.309 

Summary of Contents for PGC6

Page 1: ...Instruction Manual Gas Chargrill PGC6 PGC6P...

Page 2: ......

Page 3: ...aning Instructions 7 Maintenance Instructions 8 Conversion Instructions 9 Technical Information 10 11 Fault Finding 12 Service Information 12 Exploded View 13 Parts List 13 14 Replacement Parts 15 16...

Page 4: ...ly responsive and complies with gas safety regulations This model is designed to cook using lava rock for the distinctive smoky aroma and taste The unit leads the industry in Design and aesthetic appe...

Page 5: ...Installation and Use Regulations and the Health and Safety at Work Act All commercial gas catering equipment is recommended to be mounted below an extraction canopy Please consult a ventilation engin...

Page 6: ...be blocked at any time SEE TECHNICAL DETAILS Appliances are designed to be installed on Parry Catering Equipment for stability should they be fitted on any other surface they should be suitably secure...

Page 7: ...ed such that there are no sharp bends or torsional strain which may cause damage or failure of the tube or hose especially near the end fittings Torsional strain can be prevented by using internal uni...

Page 8: ...direction through the gradients to This is the lowest setting which has been set at the factory and must not be adjusted by user To turn burner off turn knob in a clockwise direction all the way to r...

Page 9: ...y use Allow unit to cool down before cleaning Turn off gas supply Wipe down the machine with a soft cloth do not use abrasive materials Drip trays must be emptied regularly Stainless steel cleaners ma...

Page 10: ...rts For more information on buying spares visit www parry co uk parry commercial catering spares To facilitate maintenance it is recommended that the cooking grid is removed and also the lava rock tra...

Page 11: ...ut by turning anticlockwise Replace the pilot injector with the appropriate pilot injector for the gas type being changed to from the conversion kit provided Reassemble the pipe onto the pilot and tig...

Page 12: ...Total Heat Input NATURAL G20 20mb 8 W G 5 43 KW 18 527 Btu h PROPANE G31 37mb 14 8 W G 5 43 KW 18 527 Btu h Gas Rate M HR FT HR LB HR KG HR NATURAL G20 0 500 17 95 PROPANE G31 0 205 7 24 0 875 0 397...

Page 13: ...otal Heat Input NATURAL G20 20mb 8 W G 1 777 KW 6 062 Btu h PROPANE G31 37mb 14 8 W G 1 976 KW 5779 Btu h Gas Rate M HR FT HR LB HR KG HR NATURAL G20 0 177 6 2467 PROPANE G31 0 081 2 855 0 340 0 154 G...

Page 14: ...ial 12 month warranty period will cause the 24 month warranty to become void If the supply cord becomes damaged it must be replaced by the manufacturer it s service agent or a similarly qualified pers...

Page 15: ...pose IN173 4 13 Exploded View Parts List Part Number Description Part No 1 Cooking Grid No Code 2 Lava Rock Grid No Code 3 False Flue No Code 4 BURNER BOX CHARBOX01 5 Chargrill Lifting Gear LCB00036 6...

Page 16: ...16 Gas Valve FSD GASTAP8 1 16a 8mm Olive OLVCOMPR8 16b Nut 8mm Tube NUTTUB8MM 17 Gas Valve Saddle Bracket BRACKET01 18 Injector INJECT130 NAT INJECT082 LPG 18a 8mm Olive Part of above 18b 8mm Compress...

Page 17: ...fitted when replacing the generator Flame safety device Spark Ignitor To replace thermocouple Undo the nut holding the thermocouple at the rear of the cock and loosen the clamping bracket at the burn...

Page 18: ...he loose spigot is pushed firmly into its housing and seat the rubber washer in the recess provided Refit the saddle bracket and the tighten the two screws Refit float rail assembly Reconnect gas feed...

Page 19: ...llation date of the equipment To be eligible for a 2 year warranty products must be serviced at least once within the first 12 months of purchase All service calls will be carried out between 8am and...

Page 20: ...Parry British Built for Purpose IN173 4 18 Disposal Recycling The packaging should be disposed of in accordance with the regulations in force...

Reviews: