Parry
-British Built for Purpose
IN173-4
15
Replacement Parts
Only to be carried out by a gas safe engineer
REPLACING FAULTY COMPONENTS
Disconnect from Gas and remove grid lava rock and front fascia panel.
Spark Ignitor
To replace the ignitor lead:
Pull the lead from the generator body and ignitor electrode and push the new lead
onto the terminals. Ensure that the lead is routed to avoid direct contact with the
burner flame.
To replace the spark generator body.
The generator is held on the front panel by a back nut. It is recommended that a
new ignitor lead is fitted when replacing the generator.
Flame safety device Spark Ignitor
To replace thermocouple:
Undo the nut holding the thermocouple at the rear of the cock and loosen the
clamping bracket at the burner head. Remove the faulty thermocouple.
Push the new thermocouple gently into the gas cock and tighten the nut. Do not
over tighten.
Fit the probe into the burner head bracket and tighten the screw. The probe should
be adjacent to and level with the top of a burner port ’+’.
To replace the combined flame safety/gas cock unit:
Undo the unions at injector and gas cock and remove pipe.
Undo and remove nut holding the thermocouple to the rear of the gas cock and
remove gas cock knob.
Undo the screws located above gas cock knob to release float rail assembly and
remove.